tank wall sheeting design data joints,7 off section aa …

2
A A D E F C B 3 2 1 5 4 6 7 8 C D B E F 1 2 3 4 5 6 7 8 PO BOX 145 COLLAROY BEACH, NSW 2097 AUSTRALIA [email protected] evocoengineering.com CLIENT: APPROVED DRAWN DESCRIPTION DATE REV IF THIS BAR DOES NOT MEASURE 20mm THEN DRAWING IS NOT TO SCALE ALL DIMENSIONS IN MILLIMITRES UNLESS OTHERWISE STATED APPROVED: CHECKED: DESIGNED: DRAWN: PROJECT Nº: SHEET: DRAWING Nº: ORIG. SIZE: REV.: SCALE: PROJECT: TITLE: DRAWING SET Nº 5 0 10 20 2223 WALL HEIGHT 6038 OD ASL60 - SIDE ELEVATION BOLT COVER PLATE 7 OFF REQUIRED CUSTOM ORB 16 BMT 0.42 WIDTH 762 1530 1530 6021 NOMINAL DIAMETER C L TRUSS1 ASL60 - PLAN VIEW TRUSS1 TRUSS2 TANK WALL SHEETING JOINTS,7 OFF A B DIMETRIC VIEW STRAINER MANWAY COVER LADDER DETAIL A 1:5 ISOMETRIC VIEW TRUSS SWIVEL BRACKET-ROOF RING CONNECTION DETAIL ROOF SHEETS HIDDEN FOR CLARITY GUSSET LOOSE WASHER SWIVEL BRACKET END CAP TOP RING M8 GALVANIZED BOLTS NOTES: DESIGNED WATER HEIGHT: 2.22m DESIGNED CAPACITY OF THE TANK: 61 811L DESIGN DATA The structural components have been designed in accordance with the relevant Australian Standards for the following loads: Live load to AS/NZS1170.1 and AS1657 · Roof live load = 1.1 kN, 0.25 kPa · Ladder live load = 1.5 kN Wind load to AS/NZS1170.2 · Region = A & B · Structure Importance Level = 2 · Regional wind speed V(500)= 57 m/s · Terrain category = 2.5 Earthquake load to AS1170.4 · Earthquake Design Category = Nil Atmospheric Exposure to AS4312 · Atmospheric Exposure Category = C2: Low, or T: Inland Tropical THIS DESIGN AND DRAWING IS THE SOLE PROPERTY OF EVOCO ENGINEERING PTY LTD. ANY COPY, REPRODUCTION, MODIFICATION AND/OR TRANSMITTAL OF ANY INFORMATION CONTAINED WITHIN THIS DRAWING MAY ONLY OCCURE WITH THE WRITTEN PERMISSION OF THE COMPANY. T Pisko P1 10/07/21 PRELIMINARY RELEASE P.R. ASL60-2223-WRAB-STD 1/2 A A3 C:\Users\tomas\Dropbox (Tomas)\EVOCO Engineering Pty Ltd\Projects\Bushmans Group\Aqualine Steel Tanks V2\ASL60\ PRINT DATE: Saturday, 31 July 2021 1:60 AQUALINE TANK ASL60 WIND REGION A & B GENERAL ARRANGEMENT AND DETAIL SALES DRAWING C R Rohde P Rupasinghe P Rupasinghe ASL60 GPO 4218, NSW, SYDNEY, 2001 WWW.BUSHMANTANKS.COM.AU BUSHMANS HEAD OFFICE BUSHMANS GROUP PTY LTD T.P. P.R. T.P. RELEASED FOR PRODUCTION 31/07/21 A

Upload: others

Post on 06-Feb-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TANK WALL SHEETING DESIGN DATA JOINTS,7 OFF SECTION AA …

AA

D

E

F

C

B

321 54 6 7 8

C

D

B

E

F

1 2 3 4 5 6 7 8

PO BOX 145COLLAROY BEACH, NSW 2097

AUSTRALIA

[email protected]

CLIENT:

APPROVEDDRAWNDESCRIPTIONDATEREV

IF THIS BAR DOESNOT MEASURE 20mmTHEN DRAWING IS

NOT TO SCALE

ALL DIMENSIONS INMILLIMITRES UNLESSOTHERWISE STATED

APPROVED:

CHECKED:

DESIGNED:

DRAWN:

PROJECT Nº:

SHEET:

DRAWING Nº:

ORIG. SIZE:

REV.:

SCALE: PROJECT:

TITLE:

DRAWING SET Nº50 10 20

222

3 W

ALL

HEIG

HT

6038 OD

ASL60 - SIDE ELEVATION

BOLT COVER PLATE7 OFF REQUIRED

CUSTOM ORB 16BMT 0.42 WIDTH 762

1530

15

30

6021 NOMINAL DIAMETER

CL

TRUSS1

ASL60 - PLAN VIEW

TRUSS1

TRUSS2

TANK WALL SHEETINGJOINTS,7 OFF

AB

DIMETRIC VIEW

STRAINER

MANWAY COVER

LADDER

AAAADH

E

SWIVELBRACKETCONNECTIONDETAIL

SECTION AA-AA

DETAIL A1 : 5

DETAIL A1:5

ISOMETRIC VIEWTRUSS SWIVEL BRACKET-ROOF RING CONNECTION DETAIL

ROOF SHEETS HIDDEN FOR CLARITY

GUSSET

LOOSE WASHER

SWIVEL BRACKET

END CAP

TOP RING

M8 GALVANIZED BOLTS

NOTES: DESIGNED WATER HEIGHT: 2.22mDESIGNED CAPACITY OF THE TANK: 61 811L

DESIGN DATAThe structural components have been designed in accordancewith the relevant Australian Standards for the following loads:Live load to AS/NZS1170.1 and AS1657· Roof live load = 1.1 kN, 0.25 kPa· Ladder live load = 1.5 kN

Wind load to AS/NZS1170.2· Region = A & B· Structure Importance Level = 2· Regional wind speed V(500)= 57 m/s· Terrain category = 2.5

Earthquake load to AS1170.4· Earthquake Design Category = NilAtmospheric Exposure to AS4312· Atmospheric Exposure Category = C2: Low, or T: Inland Tropical

THIS DESIGN AND DRAWING IS THE SOLE PROPERTY OF EVOCO ENGINEERING PTY LTD. ANY COPY, REPRODUCTION, MODIFICATION AND/OR TRANSMITTAL OF ANY INFORMATION CONTAINED WITHIN THIS DRAWING MAY ONLY OCCURE WITH THE WRITTEN PERMISSION OF THE COMPANY.

T PiskoP1 10/07/21 PRELIMINARY RELEASE P.R. ASL60-2223-WRAB-STD

1/2 A

A3

C:\Users\tomas\Dropbox (Tomas)\EVOCO Engineering Pty Ltd\Projects\Bushmans Group\Aqualine Steel Tanks V2\ASL60\

PRIN

T DA

TE: S

atur

day,

31 J

uly

2021

1:60 AQUALINE TANK ASL60WIND REGION A & B

GENERAL ARRANGEMENT AND DETAILSALES DRAWING

C R Rohde

P Rupasinghe

P Rupasinghe

ASL60

GPO 4218, NSW, SYDNEY, 2001

WWW.BUSHMANTANKS.COM.AU

BUSHMANS HEAD OFFICE

BUSHMANS GROUP PTY LTD

T.P.P.R.T.P.RELEASED FOR PRODUCTION31/07/21A

Page 2: TANK WALL SHEETING DESIGN DATA JOINTS,7 OFF SECTION AA …

AA

D

E

F

C

B

321 54 6 7 8

C

D

B

E

F

1 2 3 4 5 6 7 8

PO BOX 145COLLAROY BEACH, NSW 2097

AUSTRALIA

[email protected]

CLIENT:

APPROVEDDRAWNDESCRIPTIONDATEREV

IF THIS BAR DOESNOT MEASURE 20mmTHEN DRAWING IS

NOT TO SCALE

ALL DIMENSIONS INMILLIMITRES UNLESSOTHERWISE STATED

APPROVED:

CHECKED:

DESIGNED:

DRAWN:

PROJECT Nº:

SHEET:

DRAWING Nº:

ORIG. SIZE:

REV.:

SCALE: PROJECT:

TITLE:

DRAWING SET Nº50 10 20

5089 SHS

1272.5

2547.5

5095 O/A

SPLICE

ASL60 TRUSS 1 ELEVATION2 OFF HOT DIPPED GALVANIZED TRUSSES

CALCULATED MASS: 22.5 KG

CL

R19940CENTERLINE

5944 SHS 5950 O/A

1486

2975

C

SPLICE

ASL60 TRUSS 2 ELEVATION1 OFF HOT DIPPED GALVANIZED TRUSSES

CALCULATED MASS: 26.5 KG

CL

R20000CENTERLINE

226

.1

2547.5 2547.5

ASL60 TRUSS 1EXPLODED VIEW

286

2975 2975

ASL60 TRUSS 2EXPLODED VIEW

END PLATE 20

10

DETAIL C1 : 5

TRUSS END DETAIL

FLAT WASHER(LOOSE)

Ø18 FOR M16 8.8/S x90GAL BOLT

GUSSET

DETAIL B1 : 5

ISOMETRIC VIEWSPLICE PLATE CONNECTION DETAILROOF SHEETS HIDDEN FOR CLARITY

4 - M10 8.8/S x 35 GALVANIZED

THIS DESIGN AND DRAWING IS THE SOLE PROPERTY OF EVOCO ENGINEERING PTY LTD. ANY COPY, REPRODUCTION, MODIFICATION AND/OR TRANSMITTAL OF ANY INFORMATION CONTAINED WITHIN THIS DRAWING MAY ONLY OCCURE WITH THE WRITTEN PERMISSION OF THE COMPANY.

T PiskoP1 01/07/21 PRELIMINARY RELEASE P.R. ASL60-2223-WRAB-STD

2/2 A

A3

C:\Users\tomas\Dropbox (Tomas)\EVOCO Engineering Pty Ltd\Projects\Bushmans Group\Aqualine Steel Tanks V2\ASL60\

PRIN

T DA

TE: S

atur

day,

31 J

uly

2021

1:40 AQUALINE TANK ASL60WIND REGION A & B

TRUSS ARRANGEMENT AND DETAILSSALES DRAWING

C R Rohde

P Rupasinghe

P Rupasinghe

ASL60

GPO 4218, NSW, SYDNEY, 2001

WWW.BUSHMANTANKS.COM.AU

BUSHMANS HEAD OFFICE

BUSHMANS GROUP PTY LTD

T.P.P.R.T.P.RELEASED FOR PRODUCTION31/07/21A