Bulletin 5715-483
Installation ManualSeries ET101
Power Amplifier forFlow Valves
Parker Hannifin GmbHHydraulic Controls DivisionGutenbergstr. 3841564 Kaarst, GermanyTel.: (+) 2131-513-0
Fax: (+) 2131-513-230www.parker.com
Copyright 2000, Parker Hannifin GmbHContents
8/19/2019 Y23_ET101
http://slidepdf.com/reader/full/y23et101 2/6
2 Parker Hannifin GmbHHydraulic Controls DivisionHydraulics
IA ET101 UK A5.PM6.5 MM
Power Amplifier for Flow ValvesSeries ET101Installation Manual
Note
This document and other information from Parker Hannifin GmbH, itssubsidiaries, sales offices and authorized distributors provide productor system options for further investigation by users having technicalexpertise. Before you select or use any product or system it is importantthat you analyse all aspects of your application and review theinformation concerning the product or system in the current product
catalogue. Due to the variety of operating conditions and applicationsfor these products or systems, the user, through his own analysis andtesting, is solely responsible for making the final selection of theproducts and systems and assuring that all performance and safetyrequirements of the application are met. The products are subject tochange by Parker Hannifin GmbH at any time without notice.
Home
8/19/2019 Y23_ET101
http://slidepdf.com/reader/full/y23et101 3/6
3 Parker Hannifin GmbHHydraulic Controls DivisionHydraulics
IA ET101 UK A5.PM6.5 MM
Power Amplifier for Flow ValvesSeries ET101Installation Manual
Features
• Modulated output signals to the control solenoidthrough four selectable commands and ramppotentiometers, adjustablefrom 0 to 100%.
• DIP switch from internal ramp generation toexternal ramp setting.
• Pulsed low loss amplifier power stage withsupporting constant current control for con-stant, temperature-independant, solenoidforces.
• Dither generator with applied frequency toimprove static characteristics.
• Diagnosis by means of diagnostic sockets aswell as LEDs for indicating working conditions.
Ordering CodeET 101
DesignSeries
ModuleType
ElectronicModule
Flow Valves
ValveSize
Module Type
Amplifier4 Scommand channels,
Up/Down ramps
Code Valve Sol.
00 TDA...LAF E16 to E 50 35mm00 TEA...LAF E16 to E 50 35mm
99 TDA...LAF E63 to E100 60mm99 TEA...LAF E63 to E100 60mm
Connection 31 pole male connector, DIN 41617Power supply filtered: 22-38V, unfiltered: 18–26VCommand voltage 0 to +10DC and 0 to -10VDCInput select voltage 5 to 30VDCPower required 40VAReference outputs +10VDC 10mAMax. solenoid output current 1.3A with 10V commandAmbient temperature 0 to 70°CRamps adjustable from 0 to 5sec.Shielded cable connection Supply connections + valve: AWG15
Commands: AWG20Fuse 2A medium lag, DIN 41571/5x20 mm
Characteristics
Electronic module for the control of proportionalthrottle valves. The valve opening and its changesare achieved by command and ramp poten-tiometers. The measured value (Volts) on themodule is indirectly proportional with the throttleopening or alternatively the resulting volume flowQ (l/min). )(
A
B Y
Home
8/19/2019 Y23_ET101
http://slidepdf.com/reader/full/y23et101 4/6
4 Parker Hannifin GmbHHydraulic Controls DivisionHydraulics
IA ET101 UK A5.PM6.5 MM
Power Amplifier for Flow ValvesSeries ET101Installation Manual
Block Diagram
Connector(Elevation B) 2
1
EMC
EN 50081-2 EN 55011EN 50082-2 ENV 50140 EN 61000-4-4 ENV 50204 EN 61000-4-5 EN 61000-4-2 EN 61000-4-6
2 Input preselection channel 24 Input preselection channel 46 Input set value lock on channel 28 Input set value lock on channel 4
16 Output +10V reference18 Output 24VDC supply
22 Input external ramp option
26 Output control solenoid
1 Input preselection channel 13 Input preselection channel 35 Input set value lock on channel 17 Input set value lock on channel 3
11 Reference potential 0V supply
13 Input ramp disable
25 Output control solenoid
27 Input external ramp option
Home
8/19/2019 Y23_ET101
http://slidepdf.com/reader/full/y23et101 5/6
5 Parker Hannifin GmbHHydraulic Controls DivisionHydraulics
IA ET101 UK A5.PM6.5 MM
Power Amplifier for Flow ValvesSeries ET101Installation Manual
Operating and Diagnostic Elements(Elevation A)
Dimensional Drawing(Eurocard)
2
6
3
7
4
8
11
9
1213
10
1415
5
1 S 1S 1
S 2
S 3
S 4
A
B
A
B
- +
0 , 1
V =
1 A
Notes:Turn off the electrical power
to this board whenever thehydraulic supply to the valveis not on.Always turn off the power tothis board before removing itfrom the card holder.
Only potential-free measuring
equipment to be used
1–4 Command potentiometersS1–S4
5–8 Green LED`s for:channel activity of the setvalues
9 Red LED (A) for:-function indicator controlsolenoid-(B not used)
10 Yellow LED for:-correct voltage supply
11 Red socket for currentdiagnostic
12 Black socket for currentdiagnostic
13 Green grip strip withreference informationfor measured values
14 UP ramp potentiometer15 DOWN ramp potentiometer
Home
8/19/2019 Y23_ET101
http://slidepdf.com/reader/full/y23et101 6/6
6 Parker Hannifin GmbHHydraulic Controls DivisionHydraulics
IA ET101 UK A5.PM6.5 MM
Power Amplifier for Flow ValvesSeries ET101Installation Manual
INSTALLATION GUIDE TO ELECTRONIC MODULESTO PROVISION OF ELECTROMAGNETIC COMPATIBILITY.
Power Supply
The utilized power supply has to comply with the EMC-standards (CE-sign, certificate of conformity).Parker is offering the following power supplies:
EX00-N01 ( 2.5 Amp.)EX00-N04 ( 5.0 Amp.)EX00-N08 (10.0 Amp.)
Relais and solenoids operating from the same supply circuit as the valve electronics have to be fittedby surge protection elements.
Wiring Cable
The wires between the installation site of the module and the peripheral units, as power supply, valvesolenoids, command signal source have to be shielded. The following wire sizes must be reached:power supply AWG 16, other connections AWG 20. The capacity should not exceed a value of approx.130 pF/m (wire/wire). The maximum cable length is 50 m. No power current lines may be placed withinthe wired shielded cables to the electronic module. The cable shield has to be connected to groundat both ends (see also chapter „Grounding“). Please be aware of ground loops.
Installation
The module has to be mounted within a conductive, shielded enclosure. Usable is i.e. an EMC-approved control cabinet. A perfect grounding of the enclosure is mandatory (see also chapter"Grounding“).
Grounding
The mounting plate of the valve has to be connected to the grounded metal machine frame. The cableshields must be tied to ground at the control cabinet. A low-ohmic potential compensation wire hasto be provided between the control cabinet and the machine frame (cable wire >AWG 7 cross section)to prevent ground loops.
Home