CE 40 aquastatic Flexible grout Watertight, flexible dirt-resistant mortar for grouts with the width up to 5 mm CHARACTERISTICS ideally smooth resistant to water absorption flexible, on heated floors poor in chromium compound mould and dirt resistant with high adhesion with very good workability parameters inside and outside SCOPE OF USE Ceresit CE 40 mortar is used for grouting ceramic, glass and stone tiles both on horizontal and vertical surfaces (with the exception of natural stone and marble that are sensitive to discoloration). Thanks to a high degree of grout’s hydrophobic property (aquasta- tic effect) water drops remain in the shape of pearls on the surface without penetrating into the structure. It is an advantage that allows for applying this grout in the places especially endangered with temporary water treatment i.e. bathrooms, showers, kitchens. It may be applied inside and outside the buildings. It is especially recommended if tiles are laid on the deformed substra- tes: heated floors, chipboards and gypsum card- boards. CE 40 complies with the requirements of the standard PN-EN 13888:2004 – class CG2 Ar W (high parameters’ grout mortars with the increased resistance to abrasion and the reduced water absorption). Ceresit CE 42 mortar should be used for grouting marble tiles. Water resistance as well as chemical resistance ensures the application of the following Ceresit grouts: CE 44, CE 47 and CE 48. Any expansion gaps between tiles, corners, wall and floor connecting points and sanitary facilities should be filled in with silicon Ceresit CS 25. SUBSTRATE PREPARATION Tiles’ edges should be free from dirt. Grouting should be done when the tiles’ fixing material is set and dried. Prior to the application it should be checked whether CE 40 mortar does not make the surface of a tile per- manently dirt. Clean tiles’ edges should be dampened with a wet sponge. APPLICATION CE 40 should be poured to the measured amount of clean water and mixed until the homogenous mass is reached without any lumps. One cannot use any rusty equipment and tools. Mortar should be laid on the sur- face of tiles with a rubber float or a trowel. After ap- prox. 15 minutes the surplus of the material should be removed with a clean wet sponge. Any dried coating should be removed with a dry cloth. Pedestrian traffic is possible after 9 hours since the time of being applied. The first contact with water is possible after 24 hours. Within 5 days after application only clean water should be used without any cleaning agents. Grout reaches its complete hydrophobic property (resistance to water absorption) after 5 days since it is applied. CERESIT C_CE40_TM_11_0904 1 Z g o d n y z n o r m a P N - E N 1 3 8 8 8 CG2 Ar W

Upload: andrijapopovic

Post on 21-Jul-2016

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: C_CE40_TM_11_0904_21

CE 40aquastaticFlexible groutWatertight, flexible dirt-resistant mortar for grouts withthe width up to 5 mm

CHARACTERISTICS� ideally smooth� resistant to water absorption� flexible, on heated floors� poor in chromium compound� mould and dirt resistant� with high adhesion� with very good workability parameters� inside and outside

SCOPE OF USECeresit CE 40 mortar is used for grouting ceramic,glass and stone tiles both on horizontal and verticalsurfaces (with the exception of natural stone andmarble that are sensitive to discoloration). Thanks to ahigh degree of grout’s hydrophobic property (aquasta-tic effect) water drops remain in the shape of pearls onthe surface without penetrating into the structure. It isan advantage that allows for applying this grout in theplaces especially endangered with temporary watertreatment i.e. bathrooms, showers, kitchens. It may beapplied inside and outside the buildings. It is especiallyrecommended if tiles are laid on the deformed substra-tes: heated floors, chipboards and gypsum card-boards. CE 40 complies with the requirements of thestandard PN-EN 13888:2004 – class CG2 Ar W (highparameters’ grout mortars with the increased resistanceto abrasion and the reduced water absorption). CeresitCE 42 mortar should be used for grouting marble tiles.Water resistance as well as chemical resistance ensuresthe application of the following Ceresit grouts: CE 44,CE 47 and CE 48. Any expansion gaps between tiles,corners, wall and floor connecting points and sanitaryfacilities should be filled in with silicon Ceresit CS 25.

SUBSTRATE PREPARATIONTiles’ edges should be free from dirt. Grouting shouldbe done when the tiles’ fixing material is set and dried.

Prior to the application it should be checked whetherCE 40 mortar does not make the surface of a tile per-manently dirt. Clean tiles’ edges should be dampenedwith a wet sponge.

APPLICATIONCE 40 should be poured to the measured amount ofclean water and mixed until the homogenous mass isreached without any lumps. One cannot use any rustyequipment and tools. Mortar should be laid on the sur-face of tiles with a rubber float or a trowel. After ap-prox. 15 minutes the surplus of the material should beremoved with a clean wet sponge. Any dried coatingshould be removed with a dry cloth. Pedestrian trafficis possible after 9 hours since the time of being applied.The first contact with water is possible after 24 hours.Within 5 days after application only clean watershould be used without any cleaning agents. Groutreaches its complete hydrophobic property (resistanceto water absorption) after 5 days since it is applied.

CER

ESIT

C_C

E40_

TM_1

1_09

04

1

Zgod

ny

zno

rma PN-EN1

3888

CG2Ar W

BAUTECHNIK

Page 2: C_CE40_TM_11_0904_21

PLEASE NOTEWork should be done in dry conditions at the air andsurface temperature ranging from +5 to +25 °C. Alldata refer to the temperature of +23 °C and relativehumidity of 50 %. In other conditions one should takefaster or slower hardening of the material into account.Too intensive removal of exceeding grout may revealthe aggregates and cause their rough surface. Intensiverinsing of the grouts may reduce the resistance to waterabsorption. Any dampened substrate, inadequate wa-ter dosing as well as heterogeneous drying conditionsmay cause discoloration. Cleaning agents with inten-sive colours should not be used. To avoid any differen-ces in colour CE 40 should be used with the same pro-duction badge number stated on the packaging. Pow-der CE 40 has irritation property, and when mixedwith water the content of cement gives the mortar alka-line reaction. Therefore skin and eyes should be pro-tected. In case of any contact of the material with eyesthey should be rinsed with water and then consultationwith a physician is recommended if necessary. Thecontent of chromium VI – below 2 ppm in the period of product validity.

OTHER INFORMATIONGrouts freshly laid should be protected against rain,dew and temperature drop below +5 °C until groutsare completely hardened and dried. This technical da-tasheet defines the range of material application andthe recommended way of conducting the work, how-ever, it cannot replace the contractor’s professionalqualification. Apart from the data provided theapplication should be done in compliance with theconstruction and safety work principles. The manufac-turer guarantees the quality of the product, however, hedoes not have any influence on the condition and theway of application. In case of any doubts individualapplication trials should be carried out. The previouslyissued data sheets become invalid with the issue of thisdata sheet.

TECHNICAL DATABase: mixture of cements with mineral

filers and polymer modifyingagents

Bulk density: approx. 1.1 kg/dm3

Mixing proportion: 0.64 l water per 2 kg1.6 l water per 5 kg

Initial maturing time: approx. 3 minutesPot life: up to 2 h.Application temperature: from +5 to +25 °CPedestrian traffic: after 9 hResistance to abrasion (according to the standard PN-EN 13888): ≤ 1000 mm3

Flexural strength (according to the standard PN-EN 13888):– in the dry conditions: ≥ 3,5 MPa,– after freeze and thaw

cycles: ≥ 3,5 MPaCompressive strength (according to the standard PN-EN 13888):– in the dry conditions: ≥ 15 MPa,– after freeze and thaw

cycles: ≥ 15 MPaShrinkage (according to the standard PN-EN 13888):

≤ 2 mm/mWater absorption (according to the standard PN-EN 13888):– after 30 min: ≤ 2 g,– after 240 min: ≤ 5 gTemperature resistance: from –30 to +70 °CConsumption with different width of tiles:Tile dimensions Width of grout amount CE 40[cm] [mm] [kg/m2]5 x 5 2 0,55 x 5 3 0,710 x 10 2 0,415 x 15 3 0,410 x 20 3 0,4Shelf life: Until 24 months since the date

of production when stored onthe pallets in dry conditions andoriginal undamaged packaging.

This product is compatible with the standard PN-EN 13888:2004, it possesses the hygiene certificate No HK/B-1330/2003 issued by Panstwowy Zaklad Higieny as well as the certificate of contact with tap water NoHK/W/0534/01/2006.

CER

ESIT

C_C

E40_

TM_1

1_09

04

2

Should you need support or advice, please consultour advisory service for architects and craftsmen onthe hotline numbers Phone: +49 211 797 0Fax: +49 211 798 2148

Build on professional solutions.

Henkel AG & Co. KGaA – BautechnikHenkelstraße 67 · D-40589 DüsseldorfTelefon +49 (0) 211/797-0 • Telefax +49 (0) 211/798 6667Internet: www.ceresit.henkel.com · E-Mail: [email protected]

The information contained herein, particularly recommendations for the handling and use of our products, is based on our professional experience.As materials and conditions may vary with each intended application, and thus are beyond our sphere of influence, we strongly recommend thatin each case sufficient tests are conducted to check the suitability of our products for their intended use. Legal liability cannot be accepted on thebasis of the contents of this data sheet or any verbal advice given, unless there is a case of wilful misconduct or gross negligence on our part.This technical data sheet supersedes all previous editions relevant to this product.

Apart from the information given here it is also important to observe the relevant guidelines and regulations of various organisations and tradeassociations as well as the respective standards of the German Standards Institute (DIN). The aforementioned characteristics are based on practicalexperience and applied testing. Warranted properties and possible uses which go beyond those warranted in this information sheet require ourwritten confirmation. All data given was obtained at an ambient and material temperature of +23 °C and 50 % relative air humidity unless specifiedotherwise. Please note that under other climatic conditions hardening can be accelerated or delayed.