source identification of a bladeless fan by using sonah in
TRANSCRIPT
Purdue UniversityPurdue e-Pubs
Publications of the Ray W. Herrick Laboratories School of Mechanical Engineering
8-27-2019
Source Identification of a Bladeless Fan by usingSONAH in Cylindrical CoordinatesWeimin ThorPurdue University, [email protected]
J Stuart BoltonPurdue University, [email protected]
Tongyang ShiPurdue University
Follow this and additional works at: https://docs.lib.purdue.edu/herrick
This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] foradditional information.
Thor, Weimin; Bolton, J Stuart; and Shi, Tongyang, "Source Identification of a Bladeless Fan by using SONAH in CylindricalCoordinates" (2019). Publications of the Ray W. Herrick Laboratories. Paper 209.https://docs.lib.purdue.edu/herrick/209
SOURCE IDENTIFICATION OF A
BLADELESS FAN BY USING SONAH
IN CYLINDRICAL COORDINATES
SCHOOL OF MECHANICAL ENGINEERING
AUGUST 27, 2019
Weimin Thor, J. Stuart Bolton, Tongyang Shi
Ray W. Herrick Laboratories, Purdue University
San Diego, California
NOISE-CON 20192019 August 26-28
Presentation available at: https://docs.lib.purdue.edu/herrick/
Introduction
Need for identifying noise source locations to better allocate noise control resources
βͺ Importance of noise source identification
Laws and Regulations
Concerns of occupational
health and safety
Eliminating noise source in the design phase
Designing efficient noise control
strategies
Environmental concern for
noise
βͺ Current noise measurement methods
Direct
Measurement
Vibration
Measurement
Acoustical
Holography
2
Introduction
Near-field Acoustical Holography (NAH)
βͺ Construct a model to describe the acoustic field generated by a source based on a near-field
microphone array measurement
βͺ Benefits
β Measurements can be taken at a distance away from the source
β Sound field can be visualized in a three-dimensional space
β Faster than a point-to-point direct measurement
βͺ Drawbacks
β Economically costly due to number of microphones required
Noise Source
Array Measurement
Transfer Path
Reconstruction
3
Introduction
Motivation for new studies on acoustical holography such as Statistically Optimized Near-field
Acoustical Holography (SONAH)
βͺ Identify noise sources with flexible microphone measurement positions
βͺ Requires the use of less microphones
βͺ Wide application in the industry for noise source localization and identification
4
Contents
Goal: To identify source locations at various frequencies for a bladeless fan with SONAH and
suggest effective noise control solutions
βͺ SONAH formulation in cylindrical coordinates
β New simplification pattern to increase calculation speed
βͺ Simple simulation results
βͺ Experimental results
β Direct intensity measurement
β Cylindrical array measurement
5
SONAH formulation (Previous work)
J. Hald, βBasic theory and properties of statistically optimized near-field acoustical holography,β
Journal of the Acoustical Society of America, 125, 2105 β 2120 (2009).
βͺ SONAH reduces the spatial windowing effects experienced by regular NAH due to spatial truncation
βͺ Described the general formulation of SONAH in Cartesian coordinates for planar applications
βͺ SONAH performs the surface-to-surface projection optimally directly in the spatial domain
βͺ Represent any sound field as a linear combination of wave functions
π ππ =
π=1
π
ππΞ¦π ππ , π = 1,β― , πΌ
βͺ Express complex pressure at any arbitrary position, π, as a linear combination of complex pressure
on the measurement surface, ππ, with its respective weighting coefficients, ππ
π π =
π=1
π½
ππ π π ππ,π
6
SONAH formulation (Previous work)
Y. T. Cho, J. S. Bolton and J. Hald, βSource visualization by using statistically optimized near-
field acoustical holography in cylindrical coordinates,β Journal of the Acoustical Society of
America, 118, 2355 β 2364 (2005).
βͺ Representing the sound fields with cylindrical wave functions
Ξ¦ππ§,π π, π, π§ β‘π»π
1πππ
π»π1ππππ
ππππππππ§π§
π π =1
2π
π=ββ
β
ΰΆ±ββ
β
ππ ππ , ππ§ Ξ¦ππ§,π π πππ§
7
SONAH formulation (Previous work)
Y. T. Cho, J. S. Bolton and J. Hald, βSource visualization by using statistically optimized near-
field acoustical holography in cylindrical coordinates,β Journal of the Acoustical Society of
America, 118, 2355 β 2364 (2005).
βͺ Expressed the reconstructed pressure and velocity at any arbitrary locations in the form of matrix
multiplications based on the equation mentioned in Haldβs paper
π π β
π=1
π½
ππ π π ππ,π = π©T ππ π π = π©T ππ πHπ + π2πβ1πHπΆ π
π’π π =1
πππ0
ππ π
ππβ π©T ππ πHπ + π2π
β1πHπ· π
8
SONAH formulation
Based on previous works, the following formulae were defined for a single reconstruction point
πHπππ=
π=ββ
β
π=ββ
β
Ξ¦ππ§π,πβ ππ,π Ξ¦ππ§π,π ππ,π =
π=ββ
β
π=ββ
βπ»π
1ππππ
π»π1ππππ
2
ππ π ππ,πβππ,π +ππ§π π§π,πβπ§π,π
πHπΆ ππ=
π=ββ
β
π=ββ
β
Ξ¦ππ§π,πβ ππ,π Ξ¦ππ§π,π π =
π=ββ
β
π=ββ
βπ»π
1 βππππ π»π
1πππ
π»π1ππππ
2 ππ π πβππ,π +ππ§π π§βπ§π,π
πHπ· ππ=
π=ββ
β
π=ββ
β
Ξ¦ππ§π,πβ ππ,π
π
ππΞ¦ππ§π,π π =
1
πππ0
π=ββ
β
π=ββ
β π»π1 β
ππππ πππ»π1 β²
πππ
π»π1ππππ
2 ππ π πβππ,π +ππ§π π§βπ§π,π
βͺ For an actual application, reconstruction points are not restricted to a single point, where a matrix
could be formed by adding an extra column for every additional point for the calculation of πHπΆ πand πHπ· π
βͺ An optimal truncation is required to limit the infinite summation in the application
9
SONAH formulation
Due to the symmetry properties for cylindrical coordinates, it is possible to significantly
increase the processing speed of the algorithm by identifying certain patterns
βͺ The ability to speed up the calculation is only valid in the special case when the measurement grid
distribution (microphone array) is identical to the desired reconstruction grid where the only difference
is the radius
βͺ πHπΆ(π) and πHπ·(π) turns into a matrix of size π½ Γ π½ , like πHπ. The pattern of the respective matrixes
are shown next where only the first column is unique and need to be calculated
10
SONAH formulation
10
π¨Hπ¨
SONAH formulation
10
π¨HπΆ, π¨Hπ·
Simulation example
Conducted a simple simulation to verify code by reconstructing pressure, velocity, and intensity
Monopoles
(Q = 1)
π =πππππΉ
4ππΉ; π’ =
1
πππ0
ππ
ππΉ=πππππΉ
πππ0
πππΉ β 1
4ππΉ2 ; πΌπ =1
2Re ππ’π
β
992 total reconstruction points
(Cir 32 Γ H 31)
11
Simulation example (Intensity)
12
True Reconstructed
MSE =Ο πΌπ,π‘ππ’π β πΌπ,πππππ
2
Ο πΌπ,π‘ππ’π2 Γ 100% = 5.7551%
Experimental results
0Β° 180Β°
FRONT
Fan information
βͺ Operating condition: Level 5
βͺ Motor rotation speed: 5000 rpm (83.33 Hz)
βͺ Number of fan blades: 9
βͺ Blade passage frequency: 750 Hz
Intensity probe information
βͺ BrΓΌel and KjΓ¦r Type 3654 Sound Intensity Probe Kit
β Type 2270 Sound Intensity System, Type 4197 Β½β Sound Intensity Microphone
Array microphones information
βͺ BrΓΌel and KjΓ¦r Type 4958 20 kHz Precision Array Microphone
13
Preliminary test shows that most of the noise is generated
by base unit of the fan containing the rotor and stator
Wind is
flowing
through
channel
Experimental results
Direct intensity measurement
βͺ Setup
βͺ Circumferential resolution is 8Β° (appx. 2 cm) and vertical resolution is 2 cm
βͺ 322 total measurement points
14
Experimental results (752 Hz)
Direct intensity measurement result at 752 Hz
βͺ At the blade passage frequency, there was a clear directivity in sound intensity distribution which
mainly radiates from the perforated intake of the fan
0Β° 180Β°FRONT
15
Experimental results (1004 Hz)
Direct intensity measurement result at 1004 Hz
βͺ At 1004 Hz, there is a single hotspot centered at the 180ΒΊ region
0Β° 180Β°FRONT
15
Experimental results
Cylindrical array measurement
βͺ Setup
βͺ 56 microphones (Cir 8 Γ H 7 configuration)
βͺ 792 total reconstruction points
7 cm
0.1429 m
0.0859 m
17
Partial field decomposition of cylindrical array measurement results
βͺ Identify and separate uncorrelated sound fields using single value decomposition of the cross-
spectral density of the measured pressure signals from all 56 microphones
βͺ Two partial sound fields were used to describe the total sound field with an approximate 94%
accuracy around the peaks corresponding to the blade passage frequency
Experimental results (752 Hz)
18
752 Hz
Experimental results (752 Hz)
Cylindrical array measurement result at blade passage frequency peak π β πππ ππ³
βͺ Displayed similar directivity pattern as the one shown in the direct intensity measurement result
15
0Β° 180Β°FRONT
Experimental results (752 Hz)
Comparison (π β πππ ππ³)
20
0Β° 180Β°FRONT
Sound Power Comparison
Direct β 29.05 dB
SONAH β 28.16 dB
Partial field decomposition of cylindrical array measurement results
βͺ Identify and separate uncorrelated sound fields using single value decomposition of the cross-
spectral density of the measured pressure signals from all 56 microphones
βͺ Two partial sound fields were used to describe the total sound field with an approximate 95%
accuracy around the peaks corresponding to the blade passage frequency
Experimental results (1004 Hz)
21
1004 Hz
Experimental results (1004 Hz)
Cylindrical array measurement result at 1004 Hz peak
βͺ Displayed hotspot centered around the 180ΒΊ region but also another hotspot at 0ΒΊ (360ΒΊ)
15
0Β° 180Β°FRONT
Experimental results (1004 Hz)
Comparison (π β ππππ ππ³)
20
0Β° 180Β°FRONT
Sound Power Comparison
Direct β 32.53 dB
SONAH β 30.39 dB
Conclusion
βͺ Directivity pattern was observed at the blade passage frequency of 752 Hz for both direct intensity
measurement and cylindrical SONAH reconstruction
β Pattern may result from direct mounting of the fan rotor to the shell, generating a modal characteristic
β Pattern could also originate in an acoustic mode forming in the cylindrical plenum space beneath the fan
rotor
β Further investigation must be performed to identify the root cause of the directivity pattern
βͺ Based on present results from both simulation and experiment, cylindrical SONAH can reproduce the
results of the intensity measurement with significant time saving
β Direct intensity experiment took 6.5 hours to complete (excluding data analysis)
β SONAH cylindrical array experiment took merely 20 seconds (excluding data analysis)
βͺ Next steps are to develop noise control and noise reduction strategies for the bladeless fan and
identify the cause of the directivity pattern and observed reflective effect
24
Acknowledgement
βͺ Midea Group β Financial support / Fan sample provider
βͺ DaZhuang He β Main programmer for the intensity scanning robot
βͺ Ang Li β Assistance for conducting the experiments
25
EA/EOU
THANK YOUWeimin Thor J. Stuart Bolton
[email protected] [email protected]
Ray W. Herrick Laboratories Ray W. Herrick Laboratories
San Diego, California
NOISE-CON 20192019 August 26-28
References
βͺ R. Steiner and J. Hald, βNear-field acoustical holography without errors and limitations caused by the use of
spatial DFT,β Proceedings of ICSV6, 1999, pp. 843 β 850.
βͺ J. Hald, βPatch near-field acoustical holography using a new statistically optimal method,β Proceedings of Inter-
Noise 2003, 2003, pp. 2203 β 2210.
βͺ J. Hald, βBasic theory and properties of statistically optimized near-field acoustical holography,β Journal of the
Acoustical Society of America, 125, 2105 β 2120 (2009).
βͺ Y. T. Cho, J. S. Bolton and J. Hald, βSource visualization by using statistically optimized near-field acoustical
holography in cylindrical coordinates,β Journal of the Acoustical Society of America, 118, 2355 β 2364 (2005).
βͺ E. G. Williams, Fourier Acoustics: Sound Radiation and Nearfield Acoustical Holography, (Academic Press,
London, UK, 1999).
βͺ M. Abramowitz and I. A. Stegun, Handbook of Mathematical Functions with Formulas, Graphs, and
Mathematical Tables, (Dover Publications, New York, NY, 1965).
βͺ M. Lee and J. S. Bolton, βScan-based near-field acoustical holography and partial field decomposition in the
presence of noise and source level variation,β Journal of the Acoustical Society of America, 119, 382 β 393
(2006).
Simulation example
Pressure
MSE =Ο ππ‘ππ’π β ππππππ 2
Ο ππ‘ππ’π 2Γ 100% = 1.2787%
Simulation example
Velocity
MSE =Ο π’π,π‘ππ’π β π’π,πππππ
2
Ο π’π,π‘ππ’π2 Γ 100% = 9.4579%