radiation concentrations measured at the multi...
TRANSCRIPT
無断複製・転載禁止 東京電力ホールディングス株式会社 0
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet
(as of March 31, 2020)
無断複製・転載禁止 東京電力ホールディングス株式会社 1
0.01
0.1
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Cesiu
m-1
37 C
oncentr
ation (
Bq/L
)
Existing ALPS (Cesium-137)告示濃度限度(90Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
0.01
0.1
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Cesiu
m-1
37 C
oncentr
ation (
Bq/L
)
Additionally installed ALPS (Cesium-137)告示濃度限度(90Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Cesium-137 concentration)
- - Limit for concentration required by law(90Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
- - Limit for concentration required by law(90Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 2
0.01
0.1
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Cesiu
m-1
37 C
oncentr
ation (
Bq/L
)
High-performance ALPS (Cesium-137)告示濃度限度(90Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Cesium-137 concentration)
※ 1 “ND” means that concentrations were below detectable limits.
- - Limit for concentration required by law(90Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1
■ Equipment outlet□ Equipment outlet (ND) ※1
無断複製・転載禁止 東京電力ホールディングス株式会社 3
0.01
0.1
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Cesiu
m-1
34 C
oncentr
ation (
Bq/L
)
Existing ALPS (Cesium-134)告示濃度限度(60Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
0.01
0.1
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Cesiu
m-1
34 C
oncentr
ation (
Bq/L
)
Additionally installed ALPS (Cesium-134)告示濃度限度(60Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Cesium-134 concentration)
- - Limit for concentration required by law(60Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
- - Limit for concentration required by law(60Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 4
0.01
0.1
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Cesiu
m-1
34 C
oncentr
ation (
Bq/L
)
High-performance ALPS (Cesium-134)告示濃度限度(60Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Cesium-134 concentration)
- - Limit for concentration required by law(60Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1
■ Equipment outlet□ Equipment outlet (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 5
0.01
0.1
1
10
100
1,000
10,000
100,000
1,000,000
10,000,000
100,000,000
1,000,000,000
10,000,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Str
ontium
-90 C
oncentr
ation (
Bq/L
)
Existing ALPS (Strontium-90)告示濃度限度(30Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
0.01
0.1
1
10
100
1,000
10,000
100,000
1,000,000
10,000,000
100,000,000
1,000,000,000
10,000,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Str
ontium
-90 C
oncentr
ation (
Bq
/L)
Additionally installed ALPS (Strontium-90)告示濃度限度(30Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Strontium-90 concentration)
- - Limit for concentration required by law(30Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
- - Limit for concentration required by law(30Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 6
0.01
0.1
1
10
100
1,000
10,000
100,000
1,000,000
10,000,000
100,000,000
1,000,000,000
10,000,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Str
ontium
-90 C
oncentr
ation (
Bq/L
)
High-performance ALPS (Strontium-90)告示濃度限度(30Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Strontium-90 concentration)
- - Limit for concentration required by law(30Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1
■ Equipment outlet□ Equipment outlet (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 7
0.01
0.1
1
10
100
1,000
10,000
100,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Cobalt-6
0 C
oncentr
ation (
Bq/L
)
Existing ALPS (Cobalt-60)告示濃度限度(200Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
0.01
0.1
1
10
100
1,000
10,000
100,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Cobalt-6
0 C
oncentr
ation (
Bq/L
)
Additionally installed ALPS (Cobalt-60)告示濃度限度(200Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Cobalt-60 concentration)
- - Limit for concentration required by law(200Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
- - Limit for concentration required by law(200Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 8
0.01
0.1
1
10
100
1,000
10,000
100,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Cobalt-6
0 C
oncentr
ation (
Bq/L
)
High-performance ALPS (Cobalt-60)告示濃度限度(200Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Cobalt-60 concentration)
- - Limit for concentration required by law(200Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1
■ Equipment outlet□ Equipment outlet (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 9
0.1
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Antim
ony-1
25 C
oncentr
ation (
Bq/L
)
Existing ALPS (Antimony-125)告示濃度限度(800Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
0.1
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Antim
ony-1
25 C
oncentr
ation (
Bq/L
)
Additionally installed ALPS (Antimony-125)告示濃度限度(800Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Antimony-125 concentration)
- - Limit for concentration required by law(800Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
- - Limit for concentration required by law(800Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 10
0.1
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Antim
ony-1
25 C
oncentr
ation (
Bq/L
)
High-performance ALPS (Antimony-125)告示濃度限度(800Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Antimony-125 concentration)
- - Limit for concentration required by law(800Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1
■ Equipment outlet□ Equipment outlet (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 11
0.1
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Ruth
eniu
m-1
06 C
oncentr
ation
(Bq/L
)Existing ALPS (Ruthenium-106)
告示濃度限度(100Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
0.1
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Ruth
eniu
m-1
06 C
oncentr
ation
(Bq/L
)
Additionally installed ALPS (Ruthenium-106)告示濃度限度(100Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Ruthenium-106 concentration)
- - Limit for concentration required by law(100Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
- - Limit for concentration required by law(100Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 12
0.1
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Ruth
eniu
m-1
06 C
oncentr
ation
(Bq/L
)High-performance ALPS (Ruthenium-106)
告示濃度限度(100Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Ruthenium-106 concentration)
- - Limit for concentration required by law(100Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1
■ Equipment outlet□ Equipment outlet (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 13
0.01
0.1
1
10
100
1,000
10,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Iodin
e-1
29 C
oncentr
ation (
Bq/L
)Existing ALPS (Iodine-129)
告示濃度限度(9Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
0.01
0.1
1
10
100
1,000
10,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Iodin
e-1
29 C
oncentr
ation (
Bq/L
)
Additionally installed ALPS (Iodine-129)告示濃度限度(9Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Iodine-129 concentration)
- - Limit for concentration required by law(9Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
- - Limit for concentration required by law(9Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 14
0.01
0.1
1
10
100
1,000
10,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Iodin
e-1
29 C
oncentr
ation (
Bq/L
)High-performance ALPS (Iodine-129)
告示濃度限度(9Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Iodine-129 concentration)
- - Limit for concentration required by law(9Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1
■ Equipment outlet□ Equipment outlet (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 15
1
10
100
1,000
10,000
100,000
1,000,000
10,000,000
100,000,000
1,000,000,000
10,000,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Gro
ss β
Concentr
ation (
Bq/L
)
Existing ALPS (Gross β)処理前 処理前(ND)※1
設備出口A 設備出口A(ND)※1
設備出口B 設備出口B(ND)※1
設備出口C 設備出口C(ND)※1
1
10
100
1,000
10,000
100,000
1,000,000
10,000,000
100,000,000
1,000,000,000
10,000,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Gro
ss β
Concentr
ation (
Bq/L
)
Additionally installed ALPS (Gross β)処理前 処理前(ND)※1設備出口A 設備出口A(ND)※1設備出口B 設備出口B(ND)※1設備出口C 設備出口C(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Gross β concentration)
● Prior to treatment 〇 Prior to treatment(ND) ※1
■ Equipment outlet A □ Equipment outlet A(ND) ※1
▲ Equipment outlet B △ Equipment outlet B(ND) ※1
◆ Equipment outlet C ◇ Equipment outlet C(ND) ※1
● Prior to treatment 〇 Prior to treatment(ND) ※1
■ Equipment outlet A □ Equipment outlet A(ND) ※1
▲ Equipment outlet B △ Equipment outlet B(ND) ※1
◆ Equipment outlet C ◇ Equipment outlet C(ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 16
1
10
100
1,000
10,000
100,000
1,000,000
10,000,000
100,000,000
1,000,000,000
10,000,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Gro
ss β
Concentr
ation (
Bq/L
)
High-performance ALPS (Gross β)処理前 処理前(ND)※1設備出口 設備出口(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Gross β concentration)
● Prior to treatment 〇 Prior to treatment (ND) ※1
■ Equipment outlet □ Equipment outlet (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 17
0.01
0.1
1
10
100
1,000
10,000
100,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Manganese
-54 C
oncentr
ation (
Bq/L
)
Existing ALPS (Manganese-54)告示濃度限度(1000Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
0.01
0.1
1
10
100
1,000
10,000
100,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Manganese-5
4 C
oncentr
ation (
Bq/L
)
Additionally installed ALPS (Manganese-54)告示濃度限度(1000Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Manganese-54 concentration)
- - Limit for concentration required by law(1,000Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
- - Limit for concentration required by law(1,000Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 18
0.01
0.1
1
10
100
1,000
10,000
100,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Manganese-5
4C
oncentr
ation (
Bq/L
)
High-performance ALPS (Manganese-54)告示濃度限度(1000Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Manganese-54 concentration)
- - Limit for concentration required by law(1,000Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1
■ Equipment outlet□ Equipment outlet (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 19
0.01
0.1
1
10
100
1,000
10,000
100,000
1,000,000
10,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Str
ontium
-89
Concentr
ation (
Bq/L
)
Existing ALPS (Strontium-89)告示濃度限度(300Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
0.01
0.1
1
10
100
1,000
10,000
100,000
1,000,000
10,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Str
on
tiu
m-8
9 C
on
ce
ntr
atio
n (
Bq
/L)
Additionally installed ALPS (Strontium-89)告示濃度限度(300Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Strontium-89 concentration)
- - Limit for concentration required by law(300Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
- - Limit for concentration required by law(300Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 20
0.01
0.1
1
10
100
1,000
10,000
100,000
1,000,000
10,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Str
ontium
-89
Concentr
ation (
Bq/L
)
High-performance ALPS (Strontium-89) 告示濃度限度(300Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Strontium-89 concentration)
- - Limits for concentrations required by law(300Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1
■ Equipment outlet□ Equipment outlet (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 21
0.1
1
10
100
1,000
10,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Technetium
-99
Concentr
ation (
Bq/L
)Existing ALPS (Technetium-99)
告示濃度限度(1000Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
0.1
1
10
100
1,000
10,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Technetium
-99
Concentr
ation (
Bq/L
)
Additionally installed ALPS (Technetium-99)告示濃度限度(1000Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Technetium-99 concentration)
- - Limit for concentration required by law(1,000Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
- - Limit for concentration required by law(1,000Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 22
0.1
1
10
100
1,000
10,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Technetium
-99
Concentr
ation (
Bq/L
)High-performance ALPS (Technetium-99)
告示濃度限度(1000Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Technetium-99 concentration)
- - Limit for concentration required by law((1,000Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1
■ Equipment outlet□ Equipment outlet (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 23
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Rhodiu
m-1
06
Concentr
ation (
Bq/L
)
Existing ALPS (Rhodium-106)告示濃度限度(300000Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Rhodiu
m-1
06
Concentr
ation (
Bq
/L)
Additionally installed ALPS (Rhodium-106)告示濃度限度(300000Bq/L) 処理前処理前(ND)※1 設備出口A設備出口A(ND)※1 設備出口B設備出口B(ND)※1 設備出口C設備出口C(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Rhodium-106 concentration)
- - Limit for concentration required by law(300,000Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
- - Limit for concentration required by law(300,000Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1■ Equipment outlet A□ Equipment outlet A (ND) ※1▲ Equipment outlet B△ Equipment outlet B (ND) ※1◆ Equipment outlet C◇ Equipment outlet C (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 24
1
10
100
1,000
10,000
100,000
1,000,000
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Rhodiu
m-1
06
Concentr
ation (
Bq/L
)
High-performance ALPS (Rhodium-106)告示濃度限度(300000Bq/L) 処理前処理前(ND)※1 設備出口設備出口(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Rhodium-106 concentration)
- - Limit for concentration required by law((300,000Bq/L)
● Prior to treatment〇 Prior to treatment (ND) ※1
■ Equipment outlet□ Equipment outlet (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 25
0.01
0.1
1
10
100
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Gro
ss α
Concentr
ation (
Bq/L
)Existing ALPS (Gross α)
処理前 処理前(ND)※1
設備出口A 設備出口A(ND)※1
設備出口B 設備出口B(ND)※1
設備出口C 設備出口C(ND)※1
0.01
0.1
1
10
100
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Gro
ss α
Concentr
ation (
Bq/L
)
Additionally installed ALPS (Gross α)処理前 処理前(ND)※1
設備出口A 設備出口A(ND)※1
設備出口B 設備出口B(ND)※1
設備出口C 設備出口C(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Gross α concentration)
● Prior to treatment 〇 Prior to treatment(ND) ※1■ Equipment outlet A □ Equipment outlet A(ND) ※1
▲ Equipment outlet B △ Equipment outlet B(ND) ※1◆ Equipment outlet C ◇ Equipment outlet C(ND) ※1
● Prior to treatment 〇 Prior to treatment(ND) ※1■ Equipment outlet A □ Equipment outlet A(ND) ※1
▲ Equipment outlet B △ Equipment outlet B(ND) ※1◆ Equipment outlet C ◇ Equipment outlet C(ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 26
0.01
0.1
1
10
100
2013/4/1 2013/12/12 2014/8/25 2015/5/7 2016/1/18 2016/9/30 2017/6/12 2018/2/23 2018/11/5 2019/7/19 2020/3/31
Gro
ss α
Concentr
ation (
Bq/L
)High-performance ALPS (Gross α) 処理前 処理前(ND)※1
設備出口 設備出口(ND)※1
Radiation concentrations measured at the multi-nuclide removal equipment (ALPS) outlet (Gross α concentration)
● Prior to treatment 〇 Prior to treatment (ND) ※1
■ Equipment outlet □ Equipment outlet (ND) ※1
※ 1 “ND” means that concentrations were below detectable limits.
無断複製・転載禁止 東京電力ホールディングス株式会社 27
10,000
100,000
1,000,000
10,000,000
2011/3/1 2012/6/17 2013/10/4 2015/1/21 2016/5/9 2017/8/26 2018/12/13 2020/3/31
Tritium
Concentr
ation (
Bq/L
)
Tritium (H-3) 告示濃度限度(60,000Bq/L)
H-3(RO装置入口)
[Reference]
Tritium (H-3) concentration trends at desalination (RO) equipment inlets
- - Limit for concentration required by law(600,000Bq/L)
● Tritium(desalination (RO) equipment inlets)