Page 1: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

DEDEDEDEDE

Identification System CIS

EN

0766

60-0

3-01

/13

Subj

ect t

o te

chni

cal m

odifi

catio

ns w

ithou

t not

ice,

no

liabi

lity

will

be a

ssum

ed fo

r any

det

ail.

© E

UCH

NER

Gm

bH +

Co.

KG

· TA

CIS.indd 2 05.02.13 17:38

Page 2: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

2

Internationally successful – the EUCHNER company

EUCHNER GmbH + Co. KG is a world-leading company in the area of industrial safety technology. EUCHNER has been developing and producing high-quality switching sys-tems for mechanical and systems engineering for more than 50 years.The medium-sized family-operated company based in Leinfelden, Germany, employs more than 500 people around the world, 400 in Germany alone.

In addition to the production locations in Unterböhringen and Shanghai/China, 14 sub-sidiaries and other sales partners in Germany and abroad work for our international success on the market.

Quality and innovation – the EUCHNER products

A look into the past shows EUCHNER to be a company with a great inventive spirit.We take the technological and ecological challenges of the future as an incentive for extraordinary product developments.

EUCHNER safety switches monitor safety doors on machines and installations, help to minimize dangers and risks and thereby reliably protect people and processes. Today, our products range from electromechanical and electronic components to intelligent integrated safety solutions. Safety for people, machines and products is one of our dominant themes.

We defi ne future safety technology with the highest quality standards and reliable technology. Extraordinary solutions ensure the great satisfaction of our customers. The product ranges are subdivided as follows:

Transponder-coded Safety Switches (CES) Transponder-coded Safety Switches with guard locking (CET) Interlocking and guard locking systems (Multifunctional Gate Box MGB) Access management systems (Electronic-Key-System EKS) Electromechanical Safety Switches Magnetically coded Safety Switches (CMS) Enabling Switches Safety Relays Emergency Stop Devices Hand-Held Pendant Stations and Handwheels Safety Switches with AS-Interface Joystick Switches Position Switches

Headquarters in Leinfelden-Echterdingen

madeinGermany

Logistics center in Leinfelden-Echterdingen

Production location in Unterböhringen

U2_U3_EN_2013.indd 1 08.01.13 16:01

Page 3: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

Contents

3076660-03-01/13

General Information 4 - 5

System Overview 6 - 8

Identification system CIS3 9

Read-only heads CIS3 with parallel interface 12

Read/write head CIS3 with serial interface 14

Data carrier CIS3 16

Connection cables and documentation CIS3 18

Identification system CIS3A 19

Read-only heads CIS3A with parallel interface 22

Read/write head CIS3A with serial interface 26

Data carrier CIS3A 28

Connection cables and documentation CIS3A 29

Identification system CIS3A-Mini 31

Read-only interface adapter CIS3A-Mini with parallel interface 34

Read/write interface adapter CIS3A-Mini with serial interface 36

Read/write head CIS3A-Mini 38

Data carrier CIS3A-Mini 39

Connection cables and documentation CIS3A-Mini 40

Transponder Coding (TC) 41

Mobile Hand-Held Terminal MHT-G2 43

Mobile hand-held terminal Basic unit MHT-G2-BU 44

Ordering guide mobile hand-held terminal 45

Item Index 46

Identification System CIS

Page 4: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

4

General

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Inductive Identification System CISApplications

Inductive identification systems are used for the non-contact identification of products such as tools, product carriers or containers in the entire manufacturing and logistics sector. The data carriers for the identification systems CIS are mostly programmed with a unique sequential number. The product is identified at a read station using this number and the related production data are then assigned to the product.

The data carriers are read using a completely wear-free inductive cou-pling. The read heads and data carriers are of robust design, have a high degree of protection and are designed for harsh industrial usage. The identification system will also work without problems when subject to dirt and moisture.

System overview and function

The identification system CIS essentially comprises the following com-ponents:

f Data carrier f Read-only station or read/write station with data interface

The identification systems CIS3, CIS3A and CIS3A-Mini are very similar with regard to the interfaces to the higher level control system. As a result the integration into the control system is similar. There are differences, on the one hand, in the design of the antenna and, on the other hand, in the design of the components. The special features and advantages of the individual systems as well as the related system components are divided into separate sections for the systems CIS3, CIS3A and CIS3A-Mini. The components for the different identification systems CIS3, CIS3A and CIS3A-Mini must not be mixed between the systems, i. e. a CIS3 read head is not suitable for reading a CIS3A data carrier.

The read stations and read/write stations for the CIS3 and CIS3A are fitted compactly in one housing. In the case of the CIS3A-Mini the stations are split in two for space reasons, that is interface adapter and antenna are connected via an antenna cable.

Power is supplied to the transponder and the data are transferred between the read/write station and the data carrier without using any contacts.

The CIS identification system operates on the principle of inductive coupling in the near field, based on a carrier frequency of 125 kHz. This standard frequency at the low end of the frequency band used for RFID applications makes it possible, if necessary, to even install the data carrier flush in metal. However, it will certainly be of advantage if a non-metallic material is used in the immediate area around the data carrier.

A memory chip and an antenna are fitted in the data carrier, in various shapes (transponder). The E2PROM to which data can be written (program-mable) retains the data in non-volatile form. For all standard data carriers used for CIS the following applies:

f Transponder without battery f Robust encapsulated data carrier housing with degree of protection IP67

The read-only stations communicate with the higher level control system via a 4-bit parallel interface and the read/write stations via a serial interface.

Integration for read-only operation

The identification system CIS is mostly used in installation as a read-only system with the 4-bit parallel interface. The advantage of the parallel interface is simple integration into the control system and the transparent representation of the data. Quick and therefore low-cost integration into any type of PLC is possible.

The 4 data wires, which are connected directly to the PLC via inputs and outputs (I/O), represent at a point in time a related hex digit using high/low levels (24 V/0 V). After the read station is switched on, the level on all 4 wires is initially high. If a data carrier now enters the operating distance of the read station, first the data are automatically transferred from the data carrier to the memory in the read station and stored there temporarily. In the second step, the data are actively retrieved from the memory in the read station by the control system. For the second step it is no longer necessary for the data carrier to be in the read head's operating distance.

The read station saves the data from a data carrier read until the next data carrier is fed to the read station or the read station is switched off and on again. In the case of the CIS3A-Mini it is also possible to delete the temporary memory in the read station via a reset pulse. If there is a data carrier in front of the read head, the data are transferred again automatically.

In the first step, it is signaled to the control system via the high level on the STROBE output on the read station that there is a data carrier in the operating distance and new data are available in the memory on the read station. The STROBE output is set to the high level when the first 4 hex digits on the CIS3/CIS3A and the first 8 hex digits on the CIS3A Mini are available in the memory on the read station. If in the case of the CIS3/CIS3A more than 4 hex digits are required in the application, it is necessary to wait long enough until all the digits have been transferred to the memory in the read station (see pulse diagram in the manual for the read station). If, for some reason (e. g. excessively high relative speed), it was not possible to read all the digits, on the output of the data Fhex is output as an error message from the point at which the data were no longer read from the data carrier.

In the second step, the data can be retrieved from the temporary memory in the read station by the control system. A value between 0 and 15 is rep-resented at a point in time via a combination of high/low levels on the data outputs on the read station using binary coding (high level on A=1, B=2, C=4, D=8). The first digit from the data carrier is indicated immediately on the 4-bit data wire. Using pulses from the control system on the SKIP input on the read station, a maximum of 32 hex digits (16 bytes) can be read with the CIS3/CIS3A and 8 hex digits (4 bytes) with the CIS3A Mini. Reference is to be made to the pulse diagram in the manual for the read station for information on the timing of the pulses.

If the SKIP input on the read station is maintained static at a high level, no data are transferred from the data carrier into the memory in the read station. By maintaining the SKIP signal at the high level prior to the entry of the data carrier in the operating distance, on the change in the SKIP signal to the low level the data can be read statically at this defined point in time. As long as the SKIP input is maintained at the high level, the STROBE output remains at the low level, even if there is a data carrier in the operating distance of the read head. The signaling that there is a read head in front of the read head must therefore be provided separately if you want to use this reading method. On the application of this method of control, a CIS3 data carrier can, for instance, approach the read head in the opposite direction to the arrow.

Page 5: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

5

General

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

In typical applications 2, 3 or 4 digits of these 8 (CIS3AMini) or 32 (CIS3/CIS3A) possible digits are combined to form a number and used in the application. Hereby, e. g. 150 product carriers (3 digits) with 001, 002, 003 to 150 are sequentially numbered in decimal notation. The definition of the sequence of numbers with leading zeros produces a logical series. The data carrier then has a data record address that is used to store the actual production information in the control system. In this example with 3 available digits, 999 different product carriers could be addressed in decimal notation. In the case of a 3-digit number, the data are provided on the 4-bit data wire in the following sequence: the first digit is displayed automatically, the second digit is displayed after the first SKIP pulse from the control system and the third digit is displayed after the second SKIP pulse.

There exist the following possible ways of programming the data carriers with digits:

f Order programmed data carriers f Program in-house using read/write station with serial interface f Program in-house using mobile hand-held terminal

The data carrier can be written (programmed) for read-only operation on customer request and also visibly labelled using a laser. In this case a data carrier programming and labelling information form is to be completed with the order. This form is available for download from www.euchner.de.

You will have significantly more flexibility if you have your own facility for data carrier programming. The read/write station for the related identification system with a serial interface can be used on a PC for easy

writing to the data carriers (programming). For this purpose the program-ming software Transponder Coding (TC) is installed on the PC. TC is an ASCII/hex editor with which it is easy to write to and read from the data carrier on the PC.

It is also possible to write to and read from data carriers with the aid of the portable mobile hand-held terminal MHT-G2. For this purpose a read/write head to suit the related identification system is fitted. The data carriers can be read and written (programmed) using the software Transponder Coding CE (TCCE). TCCE is an ASCII/hex editor with which it is easy to write to and read from the data carrier on the MHT.

Integration for read/write operation

In the case of read/write stations with serial interface, the data com-munication is according to the 3964R transfer protocol. The individual commands, e. g. for reading the data or writing the data, are described in the device-specific manuals. For unusual CIS applications in which data carriers must also be re-programmed during production, the application is programmed in the control system with the aid of these commands based on the 3964R transfer protocol.

Interfacing of a read/write station with serial interface to the user's PC-based application is supported by the optionally available ActiveX® modules (can be used if Microsoft Windows®-based user programs sup-port ActiveX®). CIS can thus be used in conjunction with PC-based control software or visualization software. The ActiveX® module is used here as a protocol driver for the 3964R transfer protocol. You can obtain further information on the usage of an ActiveX® module on request.

Microsoft Windows® and ActiveX® are registered trademarks of Microsoft Corporation

Block diagram identification system CIS3/CIS3A

Block diagram identification system CIS3A-Mini

0815EEEE

Serial interface

Control system PLC PC

Para

llel i

nter

face

Input

Input

Input

Input

Input

Output

Output

Read/write station

Read-only station

Static reading/ writing, data carriers with 116 bytes can be used

Static reading, data carriers with 8 digits can be used

STROBE

A

B

C

D

SKIP

Value 1

Value 2

Value 4

Value 8

RESET

0815EEEE

max. 5 m for RS232 / max. 1000 m for RS422

screened

max. 15 m max. 15 m

screened

max. 15 m

screened

Read-only head

Read/write head Static reading/ writing, data carriers with 32 digits can be used

Static or dynamic reading, data carriers with 32 digits can be used

Value 1

Value 2

Value 4

Value 8

max. 5 m

screened

max. 50 m

screened

Control system PLC PC

Serial interface

Para

llel i

nter

face

Input

Input

Input

Input

Input

Output

STROBE

A

B

C

D

SKIP

Page 6: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

6

System Overview

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Identification system Features Applications Interface adapter,

read/write head

Data carriers

CIS

3P35

X16

SH16

Y...

All i

tem

s

CIS

3P16

D08

KH

16Y

SNO

...Al

l ite

ms

CIS

3AP5

0X50

SH16

YSN

O...

All i

tem

s

CIS

3AP1

0D05

KH

01K

...Al

l ite

ms

CIS3

Read distance max. 18 mm

Dynamic reading up to 410 mm/s

Coding of recirculating

product carriers or larger tools

with standard read distances

Read-only headCIT3PL1N30-STA

071 552

Read-only head CIT3PL1N30-STR

071 950

Read/write headCIT3SX1R1G05KX

096 560

CIS3A

Read distance max. 28 mm

Dynamic reading up to 230 mm/s

Coding of slowly recircu-lating product

carriers or very large tools at

increased read distances

Read-only headCIT3APL1N30-STA

071 900

Read-only headCIT3APL1G05ST

077 805

Read/write headCIT3ASX1R1G05KX

077 890 1)

CIS3A-Mini

Miniature dimensions

Read distance max. 6.5 mm

Coding of tools or small product carriers

Interface adapterCIA3...

All items with read/write head

CIT3ASX1N12ST077 940

Key to symbolsCombination possible

Combination not permissible

Features and possible combinations for CIS components

1) To set up a programming station for CIS3A-Mini data carriers, a CIS3A read/write head can be used.

Page 7: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

7

System Overview

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Identification system CIS3

Interface adapters Read/write heads Data carriers

Rea

d on

ly

Parallel interface

integrated in the read head

CIT3PL1N30-ST... f Read-only head f Cylindrical design M30 f M12 plug connector f Axial or radial connection

(see page 12)

CIS3P35X16SH16YHNO... f Cube-shaped f Approach direction horizontal

(see page 16)

CIS3P35X16SH16YVNO... f Cube-shaped f Approach direction vertical

(see page 16)

Rea

d /

wri

te Serial interface

integrated in the read/write head

CIT3SX1R1G05KX f Read/write head f Housing according to EN 50041

f Connection terminals(see page 14)

CIS3P16D08KH16YSNO... f Cylindrical ∅ 16 mm

(see page 17)

Identification system CIS3A

Interface adapters Read/write heads Data carriers

Rea

d on

ly Parallel interface

integrated in the read head

CIT3APL1N30-STA f Read-only head f Cylindrical design M30 f M12 plug connector f Axial connection

(see page 22)

CIS3AP50X50SH16YSNO... f Square

(see page 28)

CIT3APL1G05ST f Read-only head f Housing according to EN 50041

f M12 plug connector f Axial connection

(see page 24)

Rea

d /

wri

te Serial interface

integrated in the read/write head

CIT3ASX1R1G05KX f Read/write head f Housing according to EN 50041

f Connection terminals(see page 26)

Identification system CIS3A-Mini

Interface adapters Read/write heads Data carriers

Rea

d on

ly

Parallel interface

CIT3ASX1N12ST f Read/write head f Cylindrical design M12 f M8 plug connector f Axial connection

(see page 38)

CIS3AP10D05KH01K... f Cylindrical ∅ 10 mm

(see page 39)

CIA3PL1G08 f Plug-in screw terminals

(see page 34)

Rea

d /

wri

te

Serial interface

CIA3SX1R1G08 f Plug-in screw terminals

(see page 36)

Page 8: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

8

System Overview

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Mobile hand-held terminal MHT-G2

Basic unit Accessories

MHT-G2-BU f For reading and programming the data carriers

f With touch-pen and cover for rechargeable battery compartment

(see page 44)

Rechargeable battery MHT-G2-BA(see page 45)

SD memory cardMHT-G2-SD-TCCE

f With software Transponder Coding CE (TCCE)

(see page 45)

Docking stationMHT-G2-DS

f With power supply unit and USB connecting cable

(see page 45)

Extension cable f For read/write head

(see page 45)

Read/write headCIT3-H2

f For identification system CIS3(see page 45)

Read/write headCIT3A-H2

f For identification system CIS3A(see page 45)

Read/write headCIT3A-MINI-H2

f For identification system CIS3A-Mini(see page 45)

Page 9: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

9

Identification System CIS3

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Identification System CIS3 f Low-cost read/write system with predominantly used, sepa-rate read-only heads

f Extremely compact head design, no separate interface adapter required

f Read distance maximum 18 mm f Dynamic reading with a relative speed up to 410 mm/s f Data carrier memory capacity 16 bytes E2PROM read/write f Easy connection of the read-only heads to I/O on any control system via 4-bit parallel interface (24 V)

f Read/write heads with serial interface RS232

The identification system CIS3 is the predominantly used standard system in the CIS system family. The CIS3 features compact data carriers.

Typical applications are, e. g., the coding of recirculating product carriers or larger tools. The data carriers are screwed on the product to be identi-fied or the round design is bonded in a countersunk hole. The antenna and the interface electronics are fully integrated in the read heads and the read/write head. The data carrier and the head contain stick-shaped antennae. This configuration requires mounting with the same orientation of the head and data carrier. This orientation can be seen from a printed arrow marking. This fact means that the data carrier must approach the head in the direction of the arrow. The data carriers can be read when static or even moving at relative speed in front of the read head, i. e. on moving past. As a result the system is suitable, for instance, for moving product carriers. The data carrier must always be static for writing.

Page 10: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

10

Identification System CIS3

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Page 11: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

11

Identification System CIS3

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Selection table for identification system CIS3

Connection cable Read/write heads Data carriers

Rea

d on

ly

Page 18

Read-only headCIT3PL1N30-STA

Page 12

Horizontal CIS3P35X16SH16YHNO...

Page 16

Read-only head CIT3PL1N30-STR

Page 12

VerticalCIS3P35X16SH16YVNO...

Page 16

Rea

d /

wri

te

Read/write headCIT3SX1R1G05KX

Page 14

CIS3P16D08KH16YSNO...

4322ABCD

Page 17

Possible combinations for CIS3 components

Key to symbols

L 18 Combination possible, max. read distance 18 mm

S 9 Combination possible, max. write distance 9 mm

Combination not permissible

To give you a quick overview of which CIS3 components can be combined with each other, there is a combinations table for each read head. The table will answer the following questions:

f Which data carrier can be read by the selected read head? f What is the operating distance of this combination?

Read/write heads

Data carriers

CIS3P35X16SH16Y...All items

CIS3P16D08KH16YSNO...All items

Read-only headCIT3PL1N30-STA

071 552L 18 L 14

Read-only head CIT3PL1N30-STR

071 950L 18 L 14

Read/write headCIT3SX1R1G05KX

096 560

L 18S 10

L 14S 9

Identification system CIS3

Page 12: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

12

Identification System CIS3

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

M30

x1,5

5

20

60

80

90

42

M12

x1

9016

s

m

1)1)

SW 36LED

Dimension drawing

f Parallel interface f Cylindrical design M30 f M12 plug connector f Axial or radial connection

Read-only head CIT3PL1N30-STAM12 plug, 8-pin, axial connection

Ordering table

Series Interface Connection Order no. / item

Read-only head for CIS3 Parallel

M12 plug connectoraxial connection

071 552CIT3PL1N30-STA

M12 plug connectorradial connection

071 950CIT3PL1N30-STR

Read-only heads CIT3PL1N30-ST...

For connection cable see page 18For possible combinations see page 11

Mounting instructionsOn mounting the read head and data carrier, it is to be ensured the crossing direction as per the direction of the arrow on the active face of the read head is observed.

Attention:On the usage of a screened cable the connection cable is allowed to be max. 50 m long.

Pin assignment

Pin Designation Description Wire color

1 0V/GND Ground, DC 0 V WH

2 24 V/UB Power supply, DC 24 V BN

3 A Output data wire A GN

4 B Output data wire B YE

5 C Output data wire C GY

6 D Output data wire D PK

7 SKIP Input data clock BU

8 STROBE Output data carrier active RD

- Screen Open

View on the connection side of the read head

The screen on the connection cable is connected to the read head's housing via the knurled nut on the M12 plug connector.

8

3

5

7

4

21

6

16

90

M12

x1

35

150°

1)

1)

20

42

58

80

5

M 3

0x1,

5

SW36

s

m

LED

Dimension drawing

Read-only head CIT3PL1N30-STRM12 plug, 8-pin, radial connection

For connection cable see page 18

Read distance

Cent

er o

ffset

1) Clear zone

Active face Crossing direction

Data

car

rier

Read distance

Cent

er o

ffset

Data

car

rier

1) Clear zone

Adjustment rangeActive face Crossing direction

Page 13: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

13

Identification System CIS3

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

ParameterValue

Unitmin. typ. max.

Housing material Brass (CuZn) nickel-plated

Weight 0.2 kg

Ambient temperature at UB = DC 24 V -25 - +50 °C

Degree of protection according to EN 60529 IP67

Type of installation Non-flush

Connection type M12 plug connector, 8-pin, axial or radial connection, screw terminal

Cable length - - 50 m

Operating voltage UB (regulated, residual ripple < 5 %) 20 24 28 V DC

Current consumption IB (without load current) - 65 100 1) mA

Interface/data transfer

Interface to I/O on a control system 4-bit parallel, binary coded via HIGH/LOW level

Load current per output IA (push-pull) - - 30 mA

Output voltage UA

V DCA, B, C, D, STROBE = 1 (HIGH level) UB - 3 - UB

A, B, C, D, STROBE = 0 (LOW level) 0 - 2

Input voltage UE

V DCSKIP = 1 (HIGH level) 15 - UB

SKIP = 0 (LOW level) 0 - 2

Input resistance Ri (SKIP input) - 4.5 - kOhm

LED indication Yellow: Data carrier active 2)

1) Continuous current in operation.

2) The LED illuminates yellow if there is a functional data carrier in the operating distance in front of the read head.

Technical data read-only heads CIT3PL1N30-ST...

Page 14: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

14

Identification System CIS3

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

40

11930

±0,

1

7,3

5,346,560 ±0,1

<30>40

s

m

Date

nträ

ger

40

12,5

40,5

16,5

M20x1,5

Dimension drawing

f Serial interface RS232 f Active face can be adjusted to 5 different positions

f Standard housing according to EN 50041

f Connection terminals

Read/write head CIT3SX1R1G05KX

Ordering table

Series Interface Connection Order no. / item

Read/write head for CIS3 Serial RS232 Connection terminals 096 560CIT3SX1R1G05KX

Read/write head CIT3SX1R1G05KX

For possible combinations see page 11

Serial interfaceThe individual commands for reading and writing the data carrier are in accordance with the common 3964R protocol and are described in the EUCHNER CIS3 system manual (order no. 071 652).For data carrier programming away from the system, a convenient WINDOWS®-compatible PC software application is available (Software Transponder Coding, see page 41).

Standard housingThe size of the robust housing in degree of protection IP65 is compliant with the standard EN 50041.The division into 3 assemblies permits easy mounting and straightforward replacement.

Mounting instructionsOn mounting the read/write head and data carrier, it is to be ensured the crossing direction as per the direction of the arrow on the active face of the read/write head is observed.

Attention:On the usage of a screened cable the connection cable for the serial interface is allowed to be max. 5 m long.

Pin assignment

Terminal Designation Description

1 24 V/UB Power supply, DC 24 V

2 RxD Serial interface receive

3 0V/GND Ground, DC 0 V

4 TxD Serial interface transmit

Read distance

Cent

er o

ffset

Active face Crossing direction

Data

car

rier

A B

1

Changing the active face

LED status indication

Screen bonding clamp

Undo screws

Page 15: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

15

Identification System CIS3

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

ParameterValue

Unitmin. typ. max.

Housing material Plastic

Weight 0.29 kg

Ambient temperature at UB = DC 24 V 0 - +55 °C

Degree of protection according to EN 60529 IP65

Type of installation Non-flush

Connection type Screw terminals

Operating voltage UB (regulated, residual ripple < 5 %) 20 24 28 V DC

Current consumption IB (without load current) - 80 120 mA

Interface/data transfer

Interface to the PC or to the control system Serial RS232

Transfer protocol 3964R

Data transfer rate - 9.6 - kbaud

Data format 1 start bit, 8 data bits, 1 parity bit (even parity), 1 stop bit

Cable length RS232 interface - - 5 m

LED indication Green: Ready (in operation)Yellow: Data carrier active 1)

1) The LED illuminates yellow if there is a functional data carrier in the operating distance in front of the read/write head.

Technical data read/write head CIT3SX1R1G05KX

Page 16: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

16

Identification System CIS3

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

16

35

25 O 4,5

O 8

8

4,6

Data carrier CIS3P35X16SH16Y...

Dimension drawing

Data carrier CIS3P35X16SH16Y...

Active face

f Cube-shaped design 35 x 16 mm f Data carrier horizontal or vertical f Unprogrammed or programmed

Ordering table

Series Design Version Order no. / item

Data carrier for CIS3 Cube-shaped 35 x 16 mm

Horizontal, unprogrammed 084 746CIS3P35X16SH16YHNOU

Horizontal, programmed 084 747CIS3P35X16SH16YHNOP

Vertical, unprogrammed 095 950CIS3P35X16SH16YVNOU

Vertical, programmed 095 951CIS3P35X16SH16YVNOP

Technical data

ParameterValue

Unitmin. typ. max.

Memory capacity (read/write) - 16 - bytes

Housing material Plastic PPS

Weight 0.005 kg

Degree of protection according to EN 60529 IP67

Ambient temperature -40 - +85 °C

Type of installation Screw fixing, not flush (also on metal)

Memory organizationWriteRead

Only possible in 2-byte blocksPossible byte by byte

Operating parameters on reading using read-only head CIT3PL1N30-STA or CIT3PL1N30-STR

Read distance sL 0 7 18

mmCenter offset mL in x direction (for sL = 7 mm) - - ± 23

Center offset mL in y direction (for sL = 7 mm) - - ± 8

Relative speed for reading 4 hexadecimal digitsReduction for each additional hexadecimal digit(at sL = 7 mm and mL = 0 mm in y direction)

--

--

41025 mm/s

Number of read cycles Not limited

Operating parameters on reading and writing using read/write head CIT3SX1R1G05KX

Read distance sL 0 7 18

mmWrite distance sS 0 5 10

Center offset mL /mS in x direction (at sL /sS = 5 mm) - - ± 10

Center offset mL /mS in y direction (at sL /sS = 5 mm) - - ± 8

Number of write cycles 100,000 - - cycles

For possible combinations see page 11

Crossing direction

ProgrammingThe data carrier can be written (programmed) for read-only operation with a maximum of 32 hexadecimal digits (value from 0hex to Fhex) on customer request. Standard filler digit after the customer-specific defined digits is Ehex.

The housing is permanently laser marked with the digits programmed (not including filler digits) in hexadecimal notation.

Mounting instructionsOn mounting the read head and data carrier, it is to be ensured the crossing direction as per the direction of the arrow on the active face of the read head or read/write head is observed.

16

35 25

O4,

5

O8

84,6

Active faceCrossing direction

Data carrier horizontal

Data carrier vertical

Page 17: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

17

Identification System CIS3

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

8

O16

4322EEEE

Data carrier CIS3P16D08KH16YSNO...

Dimension drawing

Data carrier CIS3P16D08KH16YSNO...

Active face

f Cylindrical design ∅ 16 mm f Unprogrammed or programmed

Ordering table

Series Design Version Order no. / item

Data carrier for CIS3 Cylindrical ∅ 16 mmUnprogrammed 088 832

CIS3P16D08KH16YSNOU

Programmed 088 833CIS3P16D08KH16YSNOP

For possible combinations see page 11

Crossing direction

ProgrammingThe data carrier can be written (programmed) for read-only operation with a maximum of 32 hexadecimal digits (value from 0hex to Fhex) on customer request. Standard filler digit after the customer-specific defined digits is Ehex.

The housing is permanently laser marked with the digits programmed (not including filler digits) in hexadecimal notation.

Notes on installation f On mounting the read head and data carrier, it is to be ensured the crossing direction as per the direction of the arrow on the active face of the read head or read/write head is observed.

f For fastening use e.g. two-component epoxy resin adhesive.

Technical data

ParameterValue

Unitmin. typ. max.

Memory capacity (read/write) - 16 - bytes

Housing material Plastic PPS

Weight 0.003 kg

Degree of protection according to EN 60529 IP67

Ambient temperature -40 - +85 °C

Type of installation Bonded, flush (also in metal) 1)

Memory organizationWriteRead

Only possible in 2-byte blocksPossible byte by byte

Operating parameters on reading using read-only head CIT3PL1N30-STA or CIT3PL1N30-STR 1)

Read distance sL 0 5 14

mmCenter offset mL in x direction (for sL = 5 mm) - - ± 18

Center offset mL in y direction (for sL = 5 mm) - - ± 6

Relative speed for reading 4 hexadecimal digitsReduction for each additional hexadecimal digit(at sL = 5 mm and mL = 0 mm in y direction)

--

--

32025 mm/s

Number of read cycles Not limited

Operating parameters on reading and writing using read/write head CIT3SX1R1G05KX 1)

Read distance sL 0 5 14

mmWrite distance sS 0 5 9

Center offset mL /mS in x direction (at sL /sS = 5 mm) - - ± 10

Center offset mL /mS in y direction (at sL /sS = 5 mm) - - ± 6

Number of write cycles 100,000 - - cycles1) On flush installation in a non-metallic material, better operating parameters as for the data carriers CIS3P35X16SH16Y... are obtained

Page 18: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

18

Identification System CIS3

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Connection cables and documentation

Dimension drawing

For read-only heads CIT3M12 socket, 8-pin, silicone-free

Ordering table

Plug connectors Cable type Cable length l [m] Order no / item

Straight VCable PVC

5 077 751C-M12F08-08X025PV05,0-ZN-077751

10 077 752C-M12F08-08X025PV10,0-ZN-077752

15 077 753C-M12F08-08X025PV15,0-ZN-077753

20 077 871C-M12F08-08X025PV20,0-ZN-077871

25 077 872C-M12F08-08X025PV25,0-ZN-077872

50 077 873C-M12F08-08X025PV50,0-ZN-077873

Technical data

ParameterValue

Unitmin. typ. max.

Plug connector 8-pin M12 female connector, straight

Connection type Screw terminal, knurled nut electrically connected to cable screen

Conductor cross-section 8 x 0.25 screened mm²

Material, outer sheath PVC

f Screened connection cable for read-only heads CIT3PL.../CIT3APL...

Ordering table

Series Comment Order no.

Manual Inductive Identification system CIS3/CIS3A PDF file as download 1) 071 652

1) Downloads available at www.euchner.de in Download/Manuals/Automation/Identification systems.

f User manual CIS3/CIS3A

∅ 6

∅ 14

"l"

8

3

5

7

4

2 1

6

1 = WH f 0 V/GND2 = BN f 24 V/UB

3 = GN f A4 = YE f B5 = GY f C6 = PK f D7 = BU f SKIP8 = RD f STROBE

Open f Screen

View of connection side

The screen on the connection cable is connected to the read head's housing via the

knurled nut on the M12 plug connector.

Page 19: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

19

Identification System CIS3A

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Inductive Identification System CIS3A f Low-cost read/write system with predominantly used, sepa-rate read-only heads

f Extremely compact head design, no separate interface adapter required

f Read distance maximum 28 mm f Dynamic reading with a relative speed up to 230 mm/s f Data carrier memory capacity 16 bytes E2PROM read/write f Easy connection of the read-only heads to I/O on any control system via 4-bit parallel interface (24 V)

f Read/write heads with serial interface RS232

The identification system CIS3A is used if somewhat larger read distances are required. As a result a larger data carrier is necessary.

The data carrier is screwed on the product to be identified. The antenna and the interface electronics are fully integrated in the read heads and the read/write head. The data carrier and the head contain round-shaped antennae. The orientation of the data carrier in relation to the head is unimportant. This fact means that the data carrier can approach the head from any direction. The data carriers can be read when static or moving at low relative speed in front of the read head, i. e. on moving past. The data carrier must always be static for writing.

Page 20: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

20

Identification System CIS3A

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Page 21: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

21

Identification System CIS3A

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Selection table for identification system CIS3A

Connection cable Read/write heads Data carriers

Rea

d on

ly

Page 29

Read-only headCIT3APL1N30-STA

Page 22

CIS3AP50X50SH16YSNO...

Page 28

Read-only head CIT3APL1G05ST

Page 24

Rea

d /

wri

te

Read/write headCIT3ASX1R1G05KX

Page 26

Possible combinations for CIS3A components

Key to symbols

L 20 Combination possible, max. read distance 20 mm

S 28 Combination possible, max. write distance 28 mm

Combination not permissible

To give you a quick overview of which CIS3A components can be combined with each other, there is a combinations table for each read head. The table will answer the following questions:

f Which data carrier can be read by the selected read head? f What is the operating distance of this combination?

Read/write heads

Data carriers

CIS3AP50X50SHYSNO...All items

Read-only headCIT3APL1N30-STA

071 900L 20

Read-only head CIT3APL1G05ST

077 805L 28

Read/write headCIT3ASX1R1G05KX

077 890

L 28S 28

Identification system CIS3A

Page 22: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

22

Identification System CIS3A

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

M30

x1,5

5

20

6080

90

42

M12

x1

9016

s

m

1)1)

SW 36LED

Dimension drawing

f Parallel interface f Cylindrical design M30 f M12 plug connector f Axial connection

Read-only head CIT3APL1N30-STAM12 plug, 8-pin, axial connection

Ordering table

Series Interface Connection Order no. / item

Read-only head for CIS3A Parallel M12 plug connectoraxial connection

071 900CIT3APL1N30-STA

Read-only head CIT3APL1N30-STA

For connection cable see page 29For possible combinations see page 21

Attention:On the usage of a screened cable the connection cable is allowed to be max. 50 m long.

Pin assignment

Pin Designation Description Wire color

1 0V/GND Ground, DC 0 V WH

2 24 V/UB Power supply, DC 24 V BN

3 A Output data wire A GN

4 B Output data wire B YE

5 C Output data wire C GY

6 D Output data wire D PK

7 SKIP Input data clock BU

8 STROBE Output data carrier active RD

- Screen Open

View on the connection side of the read head

The screen on the connection cable is connected to the read head's housing via the knurled nut on the M12 plug connector.

8

3

5

7

4

21

6

Read distance

Cent

er o

ffset

1) Clear zone

Active face

Data

car

rier

Page 23: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

23

Identification System CIS3A

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Technical data read-only head CIT3APL1N30-STA

ParameterValue

Unitmin. typ. max.

Housing material Brass (CuZn) nickel-plated

Weight 0.2 kg

Ambient temperature at UB = DC 24 V -25 - +50 °C

Degree of protection according to EN 60529 IP67

Type of installation Non-flush

Connection type M12 plug connector, 8-pin, axial connection, screw terminal

Cable length - - 50 m

Operating voltage UB (regulated, residual ripple < 5 %) 20 24 28 V DC

Current consumption IB (without load current) - 65 100 1) mA

Interface/data transfer

Interface to I/O on a control system 4-bit parallel, binary coded via HIGH/LOW level

Load current per output IA (push-pull) - - 30 mA

Output voltage UA

V DCA, B, C, D, STROBE = 1 (HIGH level) UB - 3 - UB

A, B, C, D, STROBE = 0 (LOW level) 0 - 2

Input voltage UE

V DCSKIP = 1 (HIGH level) 15 - UB

SKIP = 0 (LOW level) 0 - 2

Input resistance Ri (SKIP input) - 4.5 - kOhm

LED indication Yellow: Data carrier active 2)

1) Continuous current in operation.

2) The LED illuminates yellow if there is a functional data carrier in the operating distance in front of the read head.

Page 24: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

24

Identification System CIS3A

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

f Parallel interface f Active face can be adjusted to 5 different positions

f Standard housing according to EN 50041

f M12 plug connector f Axial connection

Ordering table

Series Interface Connection Order no. / item

Read-only head for CIS3A Parallel M12 plug connectoraxial connection

077 805CIT3APL1G05ST

Read-only head CIT3APL1G05ST

For possible combinations see page 21

Attention:On the usage of a screened cable the connection cable is allowed to be max. 50 m long.

5,3

7,3

60 ±0,113

30±

0,1

40

M12

x1

4046,5

119

12,5

40,540

16,5

s

m

Dimension drawing

Read distance

Cent

er o

ffset

Data

car

rier

LED status indication

Read-only head CIT3APL1G05STM12 plug, 8-pin, axial connection

For connection cable see page 29

Active face

A B

1

Changing the active face

Pin assignment

Pin Designation Description Wire color

1 0V/GND Ground, DC 0 V WH

2 24 V/UB Power supply, DC 24 V BN

3 A Output data wire A GN

4 B Output data wire B YE

5 C Output data wire C GY

6 D Output data wire D PK

7 SKIP Input data clock BU

8 STROBE Output data carrier active RD

- Screen Open

View on the connection side of the read head

The screen on the connection cable is connected to the read head's screen bonding clamp via the knurled nut on the M12

plug connector.

8

3

5

7

4

21

6

Undo screws

Screen bonding clamp

Page 25: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

25

Identification System CIS3A

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Technical data read-only head CIT3APL1G05ST

ParameterValue

Unitmin. typ. max.

Housing material Plastic

Weight 0.3 kg

Ambient temperature at UB = DC 24 V 0 - +50 °C

Degree of protection according to EN 60529 IP65

Type of installation Non-flush

Connection type M12 plug connector, 8-pin, axial connection, screw terminal

Cable length - - 50 m

Operating voltage UB (regulated, residual ripple < 5 %) 20 24 28 V DC

Current consumption IB (without load current) - 90 120 1) mA

Interface/data transfer

Interface to I/O on a control system 4-bit parallel, binary coded via HIGH/LOW level

Load current per output IA (push-pull) - - 30 mA

Output voltage UA

V DCA, B, C, D, STROBE = 1 (HIGH level) UB - 3 - UB

A, B, C, D, STROBE = 0 (LOW level) 0 - 2

Input voltage UE

V DCSKIP = 1 (HIGH level) 15 - UB

SKIP = 0 (LOW level) 0 - 2

Input resistance Ri (SKIP input) - 4.5 - kOhm

LED indication Green: Ready (in operation)Yellow: Data carrier active 2)

1) Continuous current in operation.

2) The LED illuminates yellow if there is a functional data carrier in the operating distance in front of the read head.

Page 26: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

26

Identification System CIS3A

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

40

11930

±0,

1

7,3

5,346,560 ±0,1

3040

s

m

Date

nträ

ger

40

12,5

40,5

16,5

M20x1,5

Dimension drawing

f Serial interface RS232 f Active face can be adjusted to 5 different positions

f Standard housing according to EN 50041

f Connection terminals

Read/write head CIT3ASX1R1G05KX

Ordering table

Series Interface Connection Order no. / item

Read/write head for CIS3A Serial RS232 Connection terminals 077 890CIT3ASX1R1G05KX

Read/write head CIT3ASX1R1G05KX

For possible combinations see page 21

Serial interfaceThe individual commands for reading and writing the data carrier are in accordance with the common 3964R protocol and are described in the EUCHNER CIS3 system manual (order no. 071 652).For data carrier programming away from the system, a convenient WINDOWS®-compatible PC software application is available (Software Transponder Coding, see page 41).

Standard housingThe size of the robust housing in degree of protection IP65 is compliant with the standard EN 50041.The division into 3 assemblies permits easy mounting and straightforward replacement.

Attention:On the usage of a screened cable the connection cable for the serial interface is allowed to be max. 5 m long.

Pin assignment

Terminal Designation Description

1 24 V/UB Power supply, DC 24 V

2 RxD Serial interface receive

3 0V/GND Ground, DC 0 V

4 TxD Serial interface transmit

Read distance

Cent

er o

ffset

Active face

Data

car

rier

A B

1

Changing the active face

LED status indication

Screen bonding clamp

Undo screws

Page 27: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

27

Identification System CIS3A

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Technical data read/write head CIT3ASX1R1G05KX

ParameterValue

Unitmin. typ. max.

Housing material Plastic

Weight 0.29 kg

Ambient temperature at UB = DC 24 V 0 - +55 °C

Degree of protection according to EN 60529 IP65

Type of installation Non-flush

Connection type Screw terminals

Operating voltage UB (regulated, residual ripple < 5 %) 20 24 28 V DC

Current consumption IB (without load current) - 80 120 mA

Interface/data transfer

Interface to the PC or to the control system Serial RS232

Transfer protocol 3964R

Data transfer rate - 9.6 - kbaud

Data format 1 start bit, 8 data bits, 1 parity bit (even parity), 1 stop bit

Cable length RS232 interface - - 5 m

LED indication Green: Ready (in operation)Yellow: Data carrier active 1)

1) The LED illuminates yellow if there is a functional data carrier in the operating distance in front of the read/write head.

Page 28: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

28

Identification System CIS3A

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

40 ±0,15

50 0,250

40±

0,15

500,

250

6

20,2

Ø4,

5

-

-

Data carrier CIS3AP50X50SH16YSNO...

Dimension drawing

Data carrier CIS3AP50X50SH...

Active face

f Square design 50 x 50 mm f Unprogrammed or programmed

Ordering table

Series Design Version Order no. / item

Data carrier for CIS3A Square 50 x 50 mmUnprogrammed 088 822

CIS3AP50X50SH16YSNOU

Programmed 088 823CIS3AP50X50SH16YSNOP

For possible combinations see page 21

ProgrammingThe data carrier can be written (programmed) for read-only operation with a maximum of 32 hexadecimal digits (value from 0hex to Fhex) on customer request. Standard filler digit after the customer-specific defined digits is Ehex.

The housing is permanently laser marked with the digits programmed (not including filler digits) in hexadecimal notation.

Technical data

ParameterValue

Unitmin. typ. max.

Memory capacity (read/write) - 16 - bytesHousing material Plastic PPSWeight 0.07 kgDegree of protection according to EN 60529 IP67Ambient temperature -20 - +85 °CType of installation Screw fixing, not flush (also on metal)Memory organizationWriteRead

Only possible in 2-byte blocksPossible byte by byte

Operating parameters on reading using read-only head CIT3APL1N30-STARead distance sL 7 1) 12 20

mmCenter offset mL (for sL = 12 mm) - - ± 11Relative speed for reading 4 hexadecimal digitsReduction for each additional hexadecimal digit(at sL = 12 mm and mL = 0 mm)

--

--

20025 mm/s

Number of read cycles Not limitedOperating parameters on reading using read-only head CIT3APL1G05-STARead distance sL 14 1) 20 28

mmCenter offset mL (for sL = 20 mm) - - ± 13Relative speed for reading 4 hexadecimal digitsReduction for each additional hexadecimal digit(at sL = 20 mm and mL = 0 mm)

--

--

23025 mm/s

Number of read cycles Not limitedOperating parameters on reading and writing using read/write head CIT3ASX1R1G05KXRead distance sL and write distance sS 0 20 28

mmCenter offset mL /mS (at sL /sS = 20 mm) - - ± 13Number of write cycles 100,000 - - cycles

1) It is necessary to maintain the minimum distance on the approach of the data carrier from the side if the data must be transferred correctly to the read head in one transmission.

Page 29: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

29

Identification System CIS3A

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Connection cables and documentation

Dimension drawing

For read-only heads CIT3M12 socket, 8-pin, silicone-free

Ordering table

Plug connectors Cable type Cable length l [m] Order no / item

Straight VCable PVC

5 077 751C-M12F08-08X025PV05,0-ZN-077751

10 077 752C-M12F08-08X025PV10,0-ZN-077752

15 077 753C-M12F08-08X025PV15,0-ZN-077753

20 077 871C-M12F08-08X025PV20,0-ZN-077871

25 077 872C-M12F08-08X025PV25,0-ZN-077872

50 077 873C-M12F08-08X025PV50,0-ZN-077873

Technical data

ParameterValue

Unitmin. typ. max.

Plug connector 8-pin M12 female connector, straight

Connection type Screw terminal, knurled nut electrically connected to cable screen

Conductor cross-section 8 x 0.25 screened mm²

Material, outer sheath PVC

f Screened connection cable for read-only heads CIT3PL.../CIT3APL...

Ordering table

Series Comment Order no.

Manual Inductive Identification System CIS3/CIS3A PDF file as download 1) 071 652

1) Downloads available at www.euchner.de in Download/Manuals/Automation/Identification systems.

f User manual CIS3/CIS3A

∅ 6

∅ 14

"l"

8

3

5

7

4

2 1

6

1 = WH f 0 V/GND2 = BN f 24 V/UB

3 = GN f A4 = YE f B5 = GY f C6 = PK f D7 = BU f SKIP8 = RD f STROBE

Open f Screen

View of connection side

The screen on the connection cable is connected to the read head's housing via the

knurled nut on the M12 plug connector.

Page 30: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

30

Identification System CIS3A

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Page 31: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

31

Identification System CIS3A-Mini

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Inductive Identification System CIS3A-Mini f One of the smallest plug-in read heads f Interface adapter for fitting on the DIN rail in the control cabinet

f Miniature data carrier, diameter 10 x 4 mm f Read distance maximum 6.5 mm (static, on installation in non-metallic material)

f Data carrier memory capacity 116 bytes E2PROM read/write f Easy connection of the read-only adapter to I/O on any con-trol system via 4-bit parallel interface (24 V), max. 4 bytes of the data carrier usable via parallel interface

f Read/write interface adapter with serial interface RS232 or RS422, complete memory of 116 bytes usable via serial interface

The innovative identification system CIS3A-Mini is used if there is very little space to fit a data carrier to the product to be identified, or if there is very little space available for the read head.

Incredibly small dimensions characterize the CIS3A-Mini where the read/write head and data carrier are concerned. Typical applications are for example tool identification or modern, very complex compact assembly installations with small product carriers. The round data carriers are bonded in a countersunk hole. Due to the high quality design of the data carrier with ferrite core, a relatively large read distance is even achieved on installation in metal, despite the small antenna. The antenna and the interface electronics are located in separate housings and are connected via a special connection cable. The data carrier and the head contain round-shaped antennae. The orientation of the data carrier in relation to the head is unimportant. This fact means that the data carrier can approach the head from any direction. The data carrier can only be read or written if it is static in front of the read head.

The following components are necessary for the operation of a read station:

f Read head f Read-only interface adapter f Connection cable for connection of read head to interface adapter

The following components are necessary for the operation of a read/write station:

f Read head (here with read/write functionality) f Read/write interface adapter f Connection cable for connection of read head to interface adapter

Page 32: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

32

Identification System CIS3A-Mini

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Page 33: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

33

Identification System CIS3A-Mini

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Selection table for identification system CIS3A-Mini

Interface adapter Connection cable Read/write head Data carrier

Rea

d on

ly

Parallel interfaceCIA3PLG08

Page 34

Page 40

Read/write headCIT3ASX1N12ST

Page 38

CIS3AP10D05KH01K...0815EEEE

Page 39

Rea

d /

wri

te

Serial interfaceCIA3SX1R1G08

Page 36

Possible combinations for CIS3A-Mini components

Key to symbols

L 6.5 Combination possible, max. read distance 6.5 mm

S 6 Combination possible, max. write distance 6 mm

Combination not permissible

To give you a quick overview of which CIS3A-Mini components can be combined with each other, there is a combinations table for each read head. The table will answer the following questions:

f Which data carrier can be read by the selected read head? f What is the operating distance of this combination?

Read/write station

Data carriers

CIS3AP10D05KH01K...All items

Interface adapter CIA3...All items with read/write head

CIT3ASX1N12ST077 940

L 6.5S 6

Identification system CIS3A-Mini

Page 34: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

34

Identification System CIS3A-Mini

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

D ABCStr.1 Str.2 OV Skip

H1 LED-LED+H2

CIS3

STATE

ACTIVE

OV SH RSTUB

114

99

22,50

Dimension drawing

f Parallel interface f In combination with read head CIT3ASX1N12ST

f DIN rail mounting

Interface adapter CIA3PL1G08

Ordering table

Series Interface Order no. / item

Read-only adapter for CIS3A-Mini Parallel 091 875CIA3PL1G08

Read-only interface adapter CIA3PL1G08

For possible combinations see page 33

Attention: f The connection cable to the control system is allowed to be max. 15 m long.

f On the usage of a screened cable the connec-tion cable to the read head is allowed to be max. 15 m long.

f It is only ever possible to connect 1 read head per interface adapter.

Pin assignment power supply and interface

Designation Description

0V/GND Ground, DC 0 V

24 V/UB Power supply, DC 24 V

A Output data wire A

B Output data wire B

C Output data wire C

D Output data wire D

SKIP Input data clock

STROBE 1 Output data carrier active

RST Input RESET

Suitable for 35 mm DIN rail

acc. to DIN EN 60715 TH35

Pin assignment read head

Designation Description Wire color

H1 Read head antenna BN

H2 Read head antenna WH

LED + Read head LED YE

LED - Read head LED GN

SH Read head screen BK

Page 35: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

35

Identification System CIS3A-Mini

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Technical data read-only interface adapter CIA3PL1G08

ParameterValue

Unitmin. typ. max.

Housing material Plastic

Weight 0.12 kg

Ambient temperature at UB = DC 24 V 0 - +55 °C

Degree of protection according to EN 60529 IP20

Mounting 35 mm DIN rail acc. to DIN EN 60715 TH35

Connection type Plug-in screw terminals

Cable length to control system - - 15m

Cable length to read head - - 15

Operating voltage UB (regulated, residual ripple < 5 %) 20 24 28 V DC

Current consumption IB (without load current) - 65 100 1) mA

Interface/data transfer

Interface to I/O on a control system 4-bit parallel, binary coded via HIGH/LOW level

Load current per output IA (push-pull) - - 30 mA

Output voltage UA

V DCA, B, C, D, STROBE = 1 (HIGH level) UB - 3 - UB

A, B, C, D, STROBE = 0 (LOW level) 0 - 2

Input voltage UE

V DCSKIP = 1 (HIGH level) 15 - UB

SKIP = 0 (LOW level) 0 - 2

Input resistance Ri (RESET input and SKIP input) - 4.5 - kOhm

LED indication Green: Ready (in operation)Yellow: Data carrier active 2)

1) Continuous current in operation.

2) The LED illuminates yellow if there is a functional data carrier in the operating distance in front of the read head.

Page 36: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

36

Identification System CIS3A-Mini

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

f Serial interface RS232/RS422 f In combination with read head CIT3ASX1N12ST

f DIN rail mounting

Interface adapter CIA3SX1R1G08

Ordering table

Series Interface Order no. / item

Read/write interface adapter for CIS3A-Mini Serial RS232 / RS422 077 910CIA3SX1R1G08

Read/write interface adapter CIA3SX1R1G08

For possible combinations see page 33

Serial interfaceThe individual commands for reading and writing the data carrier are in accordance with the common 3964R protocol and are described in the EUCHNER CIS3 system manual (order no. 084 727).For data carrier programming away from the system, a convenient WINDOWS®-compatible PC software application is available (Software Transponder Coding, see page 41).

Attention: f On the usage of a screened cable the connec-tion cable for the serial interface is allowed to be max. 5 m long for RS232 and max. 1000 m long for RS422.

f On the usage of a screened cable the connec-tion cable to the read/write head is allowed to be max. 15 m long.

f It is only ever possible to connect 1 read head per interface adapter.

Pin assignment

Designation Description

0V/GND Ground, DC 0 V

24 V/UB Power supply, DC 24 V

TxD Serial interface transmitRS232

RxD Serial interface receive

A/TxD+ Serial interface transmit +

RS422B/TxD- Serial interface transmit -

A1/RxD+ Serial interface receive +

B1/RxD- Serial interface receive -

OUT Output data carrier active, 24 V

SH2 Screen data wire

A B1A1BRXD TDX OV SH2

H1 LED-LED+H2

CIS3

STATE

ACTIVE

OV SH1 OUTUB

114

99

22,50

Dimension drawing

Suitable for 35 mm DIN rail

acc. to DIN EN 60715 TH35

Pin assignment read head

Designation Description Wire color

H1 Read head antenna BN

H2 Read head antenna WH

LED + Read head LED YE

LED - Read head LED GN

SH1 Read head screen BK

Page 37: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

37

Identification System CIS3A-Mini

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Technical data read/write interface adapter CIA3SX1R1G08

ParameterValue

Unitmin. typ. max.

Housing material Plastic

Weight 0.12 kg

Ambient temperature at UB = DC 24 V 0 - +55 °C

Degree of protection according to EN 60529 IP20

Mounting 35 mm DIN rail acc. to DIN EN 60715 TH35

Connection type Plug-in screw terminals

Operating voltage UB (regulated, residual ripple < 5 %) 20 24 28 V DC

Current consumption IB (without load current) - 65 100 mA

Interface/data transfer

Interface to the PC or to the control system Serial RS232 / RS422(can be changed using rotary switch)

Transfer protocol 3964R

Data transfer rate (selectable with DIP switch) 9.6 - 28.8 kbaud

Data format 1 start bit, 8 data bits, 1 parity bit (even parity), 1 stop bit

Cable length RS232 interface - - 5 m

Cable length RS422 interface - - 1000

LED indication Green: Ready (in operation)Yellow: Data carrier active 1)

1) The LED illuminates yellow if there is a functional data carrier in the operating distance in front of the read/write head.

Page 38: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

38

Identification System CIS3A-Mini

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Technical data

ParameterValue

Unitmin. typ. max.

Housing material Brass (CuZn) nickel-plated

Weight 0.02 kg

Degree of protection according to EN 60529 IP65

Ambient temperature -25 - +50 °C

Type of installation Non-flush

SW 17

EUCHNER

5

8

30

M12

x132

4

39

19,7

M8x

1

1)

1)m

sDimension drawing

f Use with interface adapter CIA3... f Cylindrical design M12 f M8 plug connector f Axial connection

Read/write head CIT3ASX1N12STM8 plug, 4-pin, axial connection

Ordering table

Series Use Connection Order no. / item

Read/write head for CIS3A-Mini With interface adapter CIA3 M8 plug connectoraxial connection

077 940CIT3ASX1N12ST

Read/write head CIT3ASX1N12ST

For possible combinations see page 33

NoteThe read head CIT3ASX1N12ST has

f Read-only functionality in combination with the read-only interface adapter with parallel interface

f Read/write functionality in combination with the read/write interface adapter with serial interface

Attention:On the usage of a screened cable the connection cable to the interface adapter is allowed to be max. 15 m long.

4 (LED-)

3 (H2)1 (H1)

2 (LED+)

Pin assignment

Read distance

Cent

er o

ffset

Active face

View on the connection side of the read head

1) Clear zone

38 inserted50 to insert

Pin Designation Description Wire color

1 H1 Antenna H1 BN

2 LED + LED connection + YE

3 H2 Antenna H2 WH

4 LED - LED connection - GN

- Screen BK

The screen on the connection cable is connected to the read/write head's housing via the knurled nut on the M8 plug connector.

For connection cable see page 40

Page 39: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

39

Identification System CIS3A-Mini

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

9,980-0,05

0815EEEE

4 0+0,2

Data carrier CIS3AP10D05KH01K...

Dimension drawing

Data carrier CIS3AP10D05KH01K...

Active face

f Cylindrical design ∅ 10 mm f Unprogrammed or programmed

Ordering table

Series Design Version Order no. / item

Data carrier for CIS3A-Mini Cylindrical ∅ 10 mmUnprogrammed 077 785

CIS3AP10D05KH01K

Programmed 092 320CIS3AP10D05KH01K-P

For possible combinations see page 33

ProgrammingThe data carrier can be written (programmed) for read-only operation with a maximum of 8 hexadecimal digits (value from 0hex to Fhex) on customer request. Standard filler digit after the customer-specific defined digits is Ehex.

The housing is permanently laser marked with the digits programmed (not including filler digits) in hexadecimal notation.

Technical data

ParameterValue

Unitmin. typ. max.

Memory capacity (read/write) - 116 - bytesHousing material Plastic PPSWeight 0.001 kgDegree of protection according to EN 60529 IP67Ambient temperature -25 - +70 °CType of installation Bonded, flush (also in metal)Memory organizationWriteRead

Only possible in 4-byte blocksPossible byte by byte

Operating parameters on reading using read/write head CIT3ASX1N12ST and interface adapter CIA3PL1G08 or CIA3SX1R1G08Read distance sL for non-metallic environment 0 3 6.5

mmRead distance sL on flush installation in iron 0 3 6Read distance sL on flush installation in aluminum 0 3 5Center offset mL (for sL = 3 mm) - - ± 2.5Number of read cycles Not limitedOperating parameters on writing using read/write head CIT3ASX1N12ST and interface adapter CIA3SX1R1G08Write distance sS for non-metallic environment 0 3 6

mmWrite distance sS on flush installation in iron 0 3 5.5Write distance sS on flush installation in aluminum 0 3 4.5Center offset mS (for sS = 3 mm) - - ± 2Number of write cycles 100,000 - - cycles

Mounting instructionsFor fastening use e.g. two-component epoxy resin adhesive.

Page 40: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

40

Identification System CIS3A-Mini

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

"l"

∅4,631

22,5

∅10

30

Connection cables and documentation

Dimension drawing

For read/write head CIT3ASX1N12STM8 socket, 4-pin

Ordering table

Plug connectors Cable type Cable length l [m] Order no / item

Straight VCable PVC

2 084 641C-M08F04-04X025PV02,0-ES-084641

5 084 642C-M08F04-04X025PV05,0-ES-084642

10 084 643C-M08F04-04X025PV10,0-ES-084643

15 084 644C-M08F04-04X025PV15,0-ES-084644

Technical data

ParameterValue

Unitmin. typ. max.

Plug connectors 4-pin M8 female plug, straight

Connection type Screw terminal, knurled nut electrically connected to cable screen

Conductor cross-section 4 x 0.25 screened mm²

Material, outer sheath PVC

f Screened connection cable for read/write head CIT3ASX1N12ST

Ordering table

Series Comment Order no.

ManualInductive Identification System CIS3A-Mini PDF file as download 1) 084 727

1) Downloads available at www.euchner.de in Download/Manuals/Automation/Identification systems.

f User manual CIS3A-Mini

Crim

ped

ferr

ules

1 = BN f H12 = YE f LED +3 = WH f H24 = GN f LED

BK f Screen

View of connection side

4 (LED-)

3 (H2) 1 (H1)

2 (LED+)

The screen on the connection cable is connected to the read head's housing via the

knurled nut on the M8 plug connector.

Page 41: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

41

Identification System CIS

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Transponder Coding (TC) f Software for writing the data carriers f In conjunction with read/write stations with serial RS232 interface

DescriptionThe Transponder Coding (TC) software is an ASCII/hex editor that can be used to read and write the data carrier on the PC.The software is used in conjunction with a read/write station with serial interface.

Overview f Display of the data in ASCII and in hex nota-tion

f Byte-wise editing of the data f Storage of the data as ASCII or hex file on PC

System requirements f Operating system: Microsoft Windows® 98/ME/NT/2000/XP/Vista/7

f Processor: from Pentium 2 f Available memory: min. 64 MB f Hard disk space for the installation: approx. 20 MB

f Interface: serial

Ordering table

Designation Comment Order no. / item

SoftwareTransponder Coding On CD 067 190

Transponder Coding (TC)

Windows® is a registered trademark of Microsoft Corporation

Page 42: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

42

Identification System CIS

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Page 43: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

43Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Identification System CIS

Mobile Hand-Held Terminal MHT-G2The mobile hand-held terminal MHT-G2 supplements the identification systems CIS. It makes it possible to read from and write to data carriers independent of location. The basic unit is based on the hand-held computer PSION WORKABOUT PRO with the operating system Windows® Embedded CE. The device is powered using a rechargeable lithium-ion battery. The battery in the Basic unit is charged using a docking station. The docking station can also be used for data transfer between the basic unit and a PC via a USB port. An SD memory card is inserted in the basic unit, which contains the software Transponder Coding CE (TCCE) for writing (programming) and reading the data carriers. A read/write head to suit the data carrier is fitted to the basic unit. To achieve even more flexibility in use, the read/write head can be connected to the hand-held terminal via an optionally available coiled cable. The robust, splash-proof design (IP54) guarantees correct function even in difficult conditions in a harsh, industrial environment.

The following components are necessary for the operation of a mobile hand-held terminal:

f Basic unit f Rechargeable battery f Docking station f SD memory card with Transponder Coding CE (TCCE) f CIS3, CIS3A or CIS3A-Mini read/write head f Coiled extension cable (optional)

Windows® is a registered trademark of Microsoft Corporation

Page 44: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

44

Identification System CIS

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

f Reading, writing and editing EUCHNER CIS3, CIS3A and CIS3A-Mini data carriers

f With operating system Microsoft Windows® Embedded CE

Mobile hand-held terminal MHT-G2-BU

Mobile hand-held terminal basic unit MHT-G2-BU

Technical data

ParameterValue

Unitmin. typ. max.

Basic unit MHT-G2-BU for the connection of 1 read/write head (via TTL port)

Read/write head used To suit the data carrier used

Screen Color, touch-sensitive

Housing material Plastic

Degree of protection according to EN 60529 IP54

Dimensions Approx. 222 x 76 x 31 mm

Weight (incl. rechargeable battery and read/write head) Approx. 0.68 kg

Ambient temperature -20 - 50

Operating voltage UB (via lithium-ion rechargeable battery) - 3.7 - V DC

Docking station MHT-G2-DS for a basic unit MHT-G2-BU

Housing material Plastic

Power supply unit for docking station with plug adapter for the countries EU, GB, USA, AUS

Operating voltage (primary, 50 ... 60 Hz) 100 - 240 V AC

Windows® is a registered trademark of Microsoft Corporation

Page 45: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

45Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Identification System CIS

Ordering guide mobile hand-held terminal MHT-G2

Overview Item Designation Order no. / item

1a Mobile hand-held terminal basic unit

099 975MHT-G2-BU1b Touch-pen

1c Cover for rechargeable battery compartment

2 Rechargeable battery 099 981MHT-G2-BA

3 SD memory card with software Transponder Coding CE (TCCE)

099 982MHT-G2-SD-TCCE

4aDocking station for recharge

and for PC communication via USB

099 976MHT-G2-DS4b Power supply unit for

docking station

4c USB cable for the connection of the docking station to a PC

5 Extension cable for read/write head 071 759

6

Read/write head depending on configuration:

For identification system CIS3 071 755CIT3-H2

For identification system CIS3A 071 778CIT3A-H2

For identification system CIS3A-Mini

077 970CIT3A-MINI-H2

ManualMobile hand-held terminal MHT - PDF file as download 1) 103 702

1) Downloads available at www.euchner.de in Download/Manuals/Automation/Identification systems.

Page 46: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

Item Index

Item Order no. Page

46

Order no. Item Page

Index by item designation

CIA3PL1G08 091 875 34CIA3SX1R1G08 077 910 36CIS3AP10D05KH01K 077 785 39CIS3AP10D05KH01K-P 092 320 39CIS3AP50X50SH16YSNOP 088 823 28CIS3AP50X50SH16YSNOU 088 822 28CIS3P16D08KH16YSNOP 088 833 17CIS3P16D08KH16YSNOU 088 832 17CIS3P35X16SH16YHNOP 084 747 16CIS3P35X16SH16YHNOU 084 746 16CIS3P35X16SH16YVNOP 095 951 16CIS3P35X16SH16YVNOU 095 950 16CIT3A-H2 071 778 45CIT3A-MINI-H2 077 970 45CIT3APL1G05ST 077 805 24CIT3APL1N30-STA 071 900 22CIT3ASX1N12ST 077 940 38CIT3ASX1R1G05KX 077 890 26CIT3-H2 071 755 45CIT3PL1N30-STA 071 552 12CIT3PL1N30-STR 071 950 12CIT3SX1R1G05KX 096 560 14C-M08F04-04X025PV02,0-ES-084641 084 641 40C-M08F04-04X025PV05,0-ES-084642 084 642 40C-M08F04-04X025PV10,0-ES-084643 084 643 40C-M08F04-04X025PV15,0-ES-084644 084 644 40C-M12F08-08X025PV05,0-ZN-077751 077 751 18/29C-M12F08-08X025PV10,0-ZN-077752 077 752 18/29C-M12F08-08X025PV15,0-ZN-077753 077 753 18/29C-M12F08-08X025PV20,0-ZN-077871 077 871 18/29C-M12F08-08X025PV25,0-ZN-077872 077 872 18/29C-M12F08-08X025PV50,0-ZN-077873 077 873 18/29Extension cable for read/write head 071 759 45Manual inductive identification system CIS3/CIS3A 071 652 18/29Manual inductive identification system CIS3A-Mini 084 727 40Manual mobile hand-held terminal MHT 103 702 45MHT-G2-BA 099 981 45MHT-G2-BU 099 975 45MHT-G2-DS 099 976 45MHT-G2-SD-TCCE 099 982 45Transponder Coding software 067 190 41

067 190 Transponder Coding software 41071 552 CIT3PL1N30-STA 12071 652 Manual inductive identification system CIS3/CIS3A 18/29071 755 CIT3-H2 45071 759 Extension cable for read/write head 45071 778 CIT3A-H2 45071 900 CIT3APL1N30-STA 22071 950 CIT3PL1N30-STR 12077 751 C-M12F08-08X025PV05,0-ZN-077751 18/29077 752 C-M12F08-08X025PV10,0-ZN-077752 18/29077 753 C-M12F08-08X025PV15,0-ZN-077753 18/29077 785 CIS3AP10D05KH01K 39077 805 CIT3APL1G05ST 24077 871 C-M12F08-08X025PV20,0-ZN-077871 18/29077 872 C-M12F08-08X025PV25,0-ZN-077872 18/29077 873 C-M12F08-08X025PV50,0-ZN-077873 18/29077 890 CIT3ASX1R1G05KX 26077 910 CIA3SX1R1G08 36077 940 CIT3ASX1N12ST 38077 970 CIT3A-MINI-H2 45084 641 C-M08F04-04X025PV02,0-ES-084641 40084 642 C-M08F04-04X025PV05,0-ES-084642 40084 643 C-M08F04-04X025PV10,0-ES-084643 40084 644 C-M08F04-04X025PV15,0-ES-084644 40084 727 Manual inductive identification system CIS3A-Mini 40084 746 CIS3P35X16SH16YHNOU 16084 747 CIS3P35X16SH16YHNOP 16088 822 CIS3AP50X50SH16YSNOU 28088 823 CIS3AP50X50SH16YSNOP 28088 832 CIS3P16D08KH16YSNOU 17088 833 CIS3P16D08KH16YSNOP 17091 875 CIA3PL1G08 34092 320 CIS3AP10D05KH01K-P 39095 950 CIS3P35X16SH16YVNOU 16095 951 CIS3P35X16SH16YVNOP 16096 560 CIT3SX1R1G05KX 14099 975 MHT-G2-BU 45099 976 MHT-G2-DS 45099 981 MHT-G2-BA 45099 982 MHT-G2-SD-TCCE 45103 702 Manual mobile hand-held terminal MHT 45

Index by order numbers

Page 47: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

47

For your notes

Page 48: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

For your notes

48

Page 49: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

49

For your notes

Page 50: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

50

01/1

3

Representatives

Germany

International

ChemnitzEUCHNER GmbH + Co. KGIngenieur- und VertriebsbüroAm Vogelherd 209627 BobritzschTel. +49 37325 906000Fax +49 37325 [email protected]

DüsseldorfEUCHNER GmbH + Co. KGIngenieur- und VertriebsbüroSundernholz 2445134 EssenTel. +49 201 43083-93Fax +49 201 [email protected]

AustraliaMicromax Sensors & AutomationUnit 2, 106-110 Beaconsfield StreetSilverwater, NSW 2128Tel. +61 2 87482800Fax +61 2 [email protected]

AustriaEUCHNER GmbHSüddruckgasse 42512 TribuswinkelTel. +43 2252 42191Fax +43 2252 [email protected]

BeneluxEUCHNER (BENELUX) BVVisschersbuurt 233356 AE PapendrechtTel. +31 78 615-4766Fax +31 78 [email protected]

BrazilEUCHNER LtdaAv. Prof. Luiz Ignácio Anhaia Mello, no. 4387S. LucasSão Paulo - SP - BrasilCEP 03295-000Tel. +55 11 29182200Fax +55 11 [email protected]

CanadaIAC & Associates Inc.2180 Fasan DriveUnit AOldcastle, OntarioN0R 1L0Tel. +1 519 737-0311Fax +1 519 [email protected]

ChinaEUCHNER (Shanghai) Trading Co., Ltd.No. 8 Workshop A, Hi-Tech Zone503 Meinengda Road Songjiang201613 ShanghaiTel. +86 21 5774-7090Fax +86 21 [email protected]

Czech RepublicEUCHNER electric s.r.o.Videnská 134/10261900 BrnoTel. +420 533 443-150Fax +420 533 [email protected]

Essen/DortmundThomas Kreißlfördern - steuern - regelnHackenberghang 8a45133 Essen Tel. +49 201 84266-0Fax +49 201 [email protected]

WiesbadenEUCHNER GmbH + Co. KGIngenieur- und VertriebsbüroSchiersteiner Straße 2865187 WiesbadenTel. +49 611 98817644Fax +49 611 [email protected]

FreiburgEUCHNER GmbH + Co. KGIngenieur- und VertriebsbüroSteige 579206 BreisachTel. +49 7664 4038-33Fax +49 7664 [email protected]

HamburgEUCHNER GmbH + Co. KGIngenieur- und VertriebsbüroBleickenallee 1322763 HamburgTel. +49 40 636740-57Fax +49 40 [email protected]

MagdeburgEUCHNER GmbH + Co. KGIngenieur- und VertriebsbüroTismartraße 1039108 MagdeburgTel. +49 391 736279-22Fax +49 391 [email protected]

MünchenEUCHNER GmbH + Co. KGIngenieur- und VertriebsbüroObere Bahnhofstraße 682110 GermeringTel. +49 89 800846-85Fax +49 89 [email protected]

NürnbergEUCHNER GmbH + Co. KGIngenieur- und VertriebsbüroSteiner Straße 22a90522 OberasbachTel. +49 911 669-3829Fax +49 911 [email protected]

StuttgartEUCHNER GmbH + Co. KGIngenieur- und VertriebsbüroKohlhammerstraße 1670771 Leinfelden-EchterdingenTel. +49 711 7597-0Fax +49 711 [email protected]@euchner.de

DenmarkDuelco A/SSystemvej 89200 Aalborg SVTel. +45 7010 1007Fax +45 7010 [email protected]

FinlandSähkölehto OyHolkkitie 1400880 HelsinkiTel. +358 9 7746420Fax +358 9 [email protected]

FranceEUCHNER France S.A.R.L.Parc d‘Affaires des BellevuesAllée Rosa LuxembourgBâtiment le Colorado95610 ERAGNY sur OISETel. +33 1 3909-9090Fax +33 1 [email protected]

Hong KongImperial Engineers & Equipment Co. Ltd.Unit B 12/F Cheung Lee Industrial Building9 Cheung Lee Street Chai WanHong KongTel. +852 2889 0292Fax +852 2889 [email protected]

HungaryEUCHNER Ges.mbHMagyarországi Fióktelep2045 TörökbálintFSD Park 2.Tel. +36 2342 8374Fax +36 2342 [email protected]

IndiaEUCHNER (India) Pvt. Ltd.401, Bremen Business Center,City Survey No. 2562, University RoadAundh, Pune - 411007Tel. +91 20 64016384Fax +91 20 [email protected]

IsraelIlan & Gavish Automation Service Ltd.26 Shenkar St. Qiryat Arie 49513P.O. Box 10118Petach Tikva 49001Tel. +972 3 9221824Fax +972 3 [email protected]

ItalyTRITECNICA S.r.l.Viale Lazio 2620135 MilanoTel. +39 02 541941Fax +39 02 [email protected]

JapanEUCHNER Representative Office Japan8-20-24 KamitsurumahonchoMinami-ku, Sagamihara-shiKanagawa 252-0318Tel. +81 42 8127767Fax +81 42 [email protected]

Solton Co. Ltd.2-13-7, Shin-YokohamaKohoku-ku, YokohamaJapan 222-0033Tel. +81 45 471-7711Fax +81 45 [email protected]

KoreaEUCHNER Korea Co., Ltd.RM 810 Daerung Technotown 3rd#448 Gasang-DongGumcheon-gu, SeoulTel. +82 2 2107-3500Fax +82 2 [email protected]

MexicoSEPIA S.A. de C.V.Maricopa # 10302, Col. Napoles.Del. Benito Juarez03810 Mexico D.F.Tel. +52 55 55367787Fax +52 55 [email protected]

PolandELTRONPl. Wolnosci 7B50-071 WrocławTel. +48 71 3439755Fax +48 71 [email protected]

Republic of South AfricaRUBICON ELECTRICAL DISTRIBUTORS4 Reith Street, Sidwell6061 Port ElizabethTel. +27 41 451-4359Fax +27 41 [email protected]

RomaniaFirst Electric SRLStr. Ritmului Nr. 1 Bis Ap. 2, Sector 2021675 BucurestiTel. +40 21 2526218Fax +40 21 [email protected]

SingaporeSentronics Automation & Marketing Pte Ltd.Blk 3, Ang Mo Kio Industrial Park 2A#05-06Singapore 568050Tel. +65 6744 8018Fax +65 6744 [email protected]

SlovakiaEUCHNER electric s.r.o.Videnská 134/10261900 BrnoTel. +420 533 443-150Fax +420 533 [email protected]

SloveniaSMM proizvodni sistemi d.o.o.Jaskova 182000 MariborTel. +386 2 4502326Fax +386 2 [email protected]

SpainEUCHNER, S.L.Gurutzegi 12 - Local 1Polígono Belartza20018 San SebastianTel. +34 943 316-760Fax +34 943 [email protected]

SwedenCensit ABBox 33133123 VärnamoTel. +46 370 691010Fax +46 370 [email protected]

SwitzerlandEUCHNER AGGrofstrasse 178887 MelsTel. +41 81 720-4590Fax +41 81 [email protected]

TaiwanDaybreak Int‘l (Taiwan) Corp.3F, No. 124, Chung-Cheng RoadShihlin 11145, TaipeiTel. +886 2 8866-1234Fax +886 2 [email protected]

TurkeyEntek Otomasyon Urunleri San.ve Tic.Ltd.Sti.Perpa Tic.Mer. B BlokKat: 11 No:1622 - 162334384 Okmeydani / IstanbulTel. +90 212 320-2000 / 01Fax +90 212 [email protected]

United KingdomEUCHNER (UK) Ltd.Unit 2 Petre Drive,SheffieldSouth YorkshireS4 7PZTel. +44 114 2560123Fax +44 114 [email protected]

USAEUCHNER USA Inc.6723 Lyons StreetEast Syracuse, NY 13057Tel. +1 315 701-0315Fax +1 315 [email protected]

EUCHNER USA Inc.Detroit Office130 Hampton CircleRochester Hills, MI 48307Tel. +1 248 537-1092Fax +1 248 [email protected]

www.euchner.com

Support hotline You have technical questions about our products or how they can be used?For further questions please contact your local sales representative.

Comprehensive download area You are looking for more information about our products?You can simply and quickly download operating instructions, CAD or ePLAN data and accompanying software for our products at www.euchner.com.

Customer-specifi c solutionsYou need a specifi c solution or have a special requirement?Please contact us. We can manufacture your custom product even in small quantities.

EUCHNER near youYou are looking for a contact at your location? Along with the headquarters in Leinfel-den-Echterdingen, the worldwide sales network includes 14 subsidiaries and numerous representatives in Germany and abroad – you will defi nitely also fi nd us near you.

U2_U3_EN_2013.indd 2 08.01.13 16:01Adressen neu DE EN FR IT ES.indd 50 25.01.2013 17:00:58

Page 51: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

51

www.euchner.com

Support hotline You have technical questions about our products or how they can be used?For further questions please contact your local sales representative.

Comprehensive download area You are looking for more information about our products?You can simply and quickly download operating instructions, CAD or ePLAN data and accompanying software for our products at www.euchner.com.

Customer-specifi c solutionsYou need a specifi c solution or have a special requirement?Please contact us. We can manufacture your custom product even in small quantities.

EUCHNER near youYou are looking for a contact at your location? Along with the headquarters in Leinfel-den-Echterdingen, the worldwide sales network includes 14 subsidiaries and numerous representatives in Germany and abroad – you will defi nitely also fi nd us near you.

U2_U3_EN_2013.indd 2 08.01.13 16:01Adressen neu DE EN FR IT ES.indd 51 25.01.2013 17:00:58

Page 52: Identification System CIS - EUCHNER · The identification system CIS essentially comprises the following com-ponents: f Data carrier f Read-only station or read/write station with

EUCHNER GmbH + Co. KGKohlhammerstraße 1670771 Leinfelden-EchterdingenGermanyTel. +49 711 7597-0Fax +49 711 [email protected]

EN

0766

60-0

3-01

/13

Subj

ect t

o te

chni

cal m

odifi

catio

ns w

ithou

t not

ice,

no

liabi

lity

will

be a

ssum

ed fo

r any

det

ail.

© E

UCH

NER

Gm

bH +

Co.

KG

· TA

CIS.indd 1 05.02.13 17:38