    Stationary

    KAESER Rotary Screw CompressorMobilair 135 / 10 bar

    with CE mark and Declaration of Conformity

    Compressor

    Free air delivery 13 m/minCompressor discharge pressure 10 bar(g) Compressor full load shaft power,incl. ventilator 105 kW

    Motor (water-cooled)

    Nominal power 122 kWSpeed, full load 2000 rpmSpeed, idling 1300 rpmMotor type 4-cylinder, dieselModel TCD 2013 L04Manufacturer Deutz

    Weights and dimensions

    DimensionsLength x breadth x height 3140 x 1820 x 1475 mmFuel tank capacity 200 litresAir outlet valve (claw coupling) 3 x G 3/4

    1 x G 2Total weight approx. 2300 kg

    Guaranteed sound power level per directive 2000/14/EC Quiet operation- Sound-attenuated, galvanised steel plate > Low noise level,-

    bodywork long service life

    Offre 8790886 - SARL Rolandtecnic Algrie 2/9

  • OFFRE

    - Gull-wing maintenance doors > Good accessibility- Stiffened underbody > Secure transportation-

    and operation- Rain-proof cover of the recessed lifting eye > Easy to crane- Corrosion-resistant, internally mounted > Protection against accident al

    exhaust gas silencer contact, long service life- Ventilator grille > Maximal operator safety

    Compressor

    - Airend with Kaeser-manufactured > Efficient, maximum costSIGMA PROFILE rotors effectiveness

    - Inlet filter with silencer > Noise level reduction, -with standard cartridge reusability ensures cost

    effectiveness- Electro-pneumatic inlet valve > Automatic operation- Relief valve on the fluid separator tank > Maximum safety- Compressor connected to diesel motor > Simple maintenance, optimal

    via flanged transmission bell housing efficiency- Generously dimensioned bearings > Long service life

    Cooling and lubrication

    - Reusable fluid separation > Minimal residual oil content ofcartridge 2-4 mg/m = 2-4 g/1000 m

    - Ventilator on the motor shaft > Intensive cooling- Supplied with fluid charged > Ready to run- Valveless fluid circulation with > Maximum reliability

    thermostat, bypass and micro filter- Fluid cooling via aluminium heat > Optimal operating temperature

    exchanger- Combined fluid reservoir and > Fast oil change

    separator tank- Optical fluid level check > Simple monitoringControls

    - Continuously variable air > Simple, automatic matchingdelivery through control of the to consumptionmotor speed and compressorinlet valve

    - Automatic venting of the equipment > Gentle, pressure-free start upafter motor shutdown of the compressor

    Safety system

    Malfunctions initiate an immediate shutdown of the equipment, and are signalledby a common fault lamp :- Maximum discharge temperature exceeded

    Offre 8790886 - SARL Rolandtecnic Algrie 3/9

  • OFFRE

    - Motor oil pressure too low- Non-charging alternator- Fuel level low

    Additional monitoring functions:- Service indicator for the air inlet filter- Start inhibitor when motor is already running

    Equipment

    - Battery isolation switch > Complete system shutdowninside the unit and lock-off against

    unauthorised operation- High capacity battery > Reliable motor starting- Fuel pre-filter fitted in line > Maximum operational reliability

    Transport- Recessed lifting eye > easy loading and unloadingInstrument panel

    - Analogue discharge pressure gauge- Analogue fuel level indicator- Emergency off button and main switch- SIGMA Control Mobile

    SIGMA CONTROL Mobilfor KAESER portable compressors

    SIGMA CONTROL Mobil is a fully developed product of theconstruction machine industry and ensures safe portable compressoroperation through display of alarm messages and simple push-buttonoperation.

    Hardware- Instrument panel with display and 12 buttons- Enclosure protection IP 65- Protected by a metal cover.

    Functions and advantages- Display of operating data and user guidance

    Offre 8790886 - SARL Rolandtecnic Algrie 4/9

  • OFFRE

    - Automatic engine regulation- Analog data processing- Function monitoring with alarm messages and fault diagnosis- Pictograms understandable in any language- Simple menu guidance- Simple switchover from warm-up/dle to load- Maintenance interval indicator counting down to next maintenanceEC directives applied

    98/37/EC Machinery directive87/404/EC Simple, unfired pressure vessels2000/14 Environmentally damaging emissions of devicesand machines used in the open air.97/23/EC Pressure Equipment Directive (for pressure relief valves, EC)2006/95/EC Low voltage regulations

    Drive engines conform to emission directives 2004/26/EC and EPA IIIa andEPA level 3.

    Harmonized norms/regulations appliedEN 1012-1 Safety requirements for compressorsEN ISO 12100-1 Safety of machines - basic terminologyEN ISO 12100-2 Safety of machines - technical guidelinesEN 294 Safety of machines - safe distances

    EN 12516-3 Fittings, housing strength, part 3: experimental processes(for existing pressure -bearing housing components).EN 60204-1 Safety of machines - electrical equipment

    The German National Equipment Safety ActThe Federal German Emission Protection Act

    Conformity evaluation procedures98/37/EC according to annex IIA2000/14/EC Internal manufacturing checks with evaluation of technicaldocuments and regular inspections in accordance with annex VI of thedirective.

    DocumentationCompressor unit:KAESER service manual including P & I flow diagram, electrical diagramsand spares lists.Engine:Engine manufacturers service manual

    Available compressed air treatment versions- Machine with a built-in compressed air aftercooler and cyclonic

    separator to remove condensate from the compressed air.- Machine with built-in compressed air heater for relative dry air.

    The compressed air heater is an oil/air heat exchanger using the hot compressor oil, at about 80C to raise the temperature of the

    Offre 8790886 - SARL Rolandtecnic Algrie 5/9

  • OFFRE

    compressed air by 5-10 K.A machine with the air treatment devices of compressed air aftercooler,cyclonic separator and air warmer will ensure that condensate doesnot form in consumers such as air tools and sand-blasting plant.

    - Machine with built-in filter to produce breathing air that can betaken off from two outlets.

    - Additional combination filter fitted downstream of the cyclonicseparator to give oil-free air suitable for concrete repair.If a tool lubricator is fitted, oiled air can be drawn from any outlet.If the lubricator is combined with air treatment devices, however,oiled air may be taken from two outlets and treated air from the others.

    Special air treatment systems available on request.

    Offre 8790886 - SARL Rolandtecnic Algrie 6/9

  • OFFRE

    Directives, normes, rglementations etrecommandations dinstallation

    Les directives suivantes peuvent tre applicables nos produits :

    2006/42/CE Directive Machines 2009/105/CE (87/404/CEE) Directive relative aux rcipients pression simples 97/23/CE Directive quipements sous pression 2006/95/CE Directive Basse tension 2004/108/CE Directive CEM

    Les directives applicables sont mentionnes dans la dclaration CE de chaque produit.

    Normes harmonises importantes :

    ISO 12100-1/-2 Scurit des machines EN 60204 Scurit des machines - quipement lectrique des machines EN 1012-1 Prescriptions de scurit - Compresseurs EN 1012-2 Prescriptions de scurit - Pompes vide (ASV, BSV, CSV) EN 378 Systmes de rfrigration et pompes chaleur (Exigences de scurit et denvironnement)

    Normes applicables aux caractristiques techniques :

    Dbit rel : selon ISO 1217:2009 annexe C

    Niveau de pression acoustique : selon ISO 2151 et la norme de base ISO 9614-2, tolrance : +/- 3 dB(A)

    Niveau de puissance acoustique : selon ISO 2151 et la norme de base ISO 9614-2, tolrance : +/- 3 dB(A)

    Offre 8790886 - SARL Rolandtecnic Algrie 8/9

  • OFFRE

    Recommandation concernant le raccordement lectrique :

    Le raccordement lectrique sur site est excuter conformment aux normes applicables (parexemple CEI 60364 ou DIN VDE 0100) et aux rglementations nationales en matire de scurit et deprvention des accidents (en Allemagne, rglement de la caisse de prvoyance professionnelle BGVA3).

    Une combinaison interrupteur principal et fusible telle quelle est prescrite par les rglementations enmatire de scurit et de prvention des accidents est prvoir sur site.

    Les prescriptions du fournisseur dlectricit local sont respecter.

    Plages de temprature admissibles sur le lieu dinstallation :

    Compresseurs en vis en gnral : +3 C +45 C sauf SXC, DSG 290-2, FSG 500-2 (refroidis par air), FSG 520-2,

    centrales de vide vis (ASV, BSV, CSV) : +3 C +40 C Surpresseurs pistons rotatifs :

    avec partie commande et puissance intgre (centrales) : +3 C +40 C sans partie commande et puissance intgre (groupes): -15 C +40 C

    Compresseurs pistons : +5 C +35 C Surpresseurs : +2 C +40 C Scheurs frigorifiques en gnral : +3 C +43 C

    sauf TAH, TBH, TCH, TG, TH, TI, TCU : +3 C +45 C

    Des ouvertures dentre et dvacuation dair correctement dimensionnes sont prvoir dans lelocal.

    Nous sommes votre disposition pour vous conseiller en la matire.

    Remarques Pour les machines refroidies par eau, veuillez respecter les spcifications de leau de refroidissement. Pour les machines quipes dun systme de rcupration de calories intgr, veuillez respecter les

    spcifications de leau de refroidissement.

    Offre 8790886 - SARL Rolandtecnic Algrie 9/9