european technical approval eta 10/0328 - cstbwebapp.cstb.fr/.../pdf/doc_eta_10_0328_uk.pdfpage 5...

23
Centre Scientifique et Technique du Bâtiment 84 avenue Jean Jaurès Champs sur Marne F-77447 Marne la Vallée Cedex 2 Tél. : (33) 01 64 68 82 82 Fax : (33) 01 60 05 70 37 Autorisé et notifié conformément à l’article 10 de la directive 89/106/EEC du Conseil, du 21 décembre 1988, relative au rapprochement des dispositions législatives, réglementaires et administratives des Etats membres concernant les produits de construction. MEMBRE DE L’EOTA European Technical Approval - ETA 10/0328 (version originale en langue française) Nom commercial : Trade name: Fibratec Ultra (Plâtre ERP Plâtre Vinyl Lambris Planche Acoustique - Particules) & Fibratec FM Ultra (Plâtre ERP Plâtre Lambris Planche) Titulaire : Holder of approval: KNAUF SAS Zone d’Activité Rue Principale 68600 WOLFGANTZEN Type générique et utilisation prévue du produit de construction : Self supporting composite lightweight panels for use in roofs. Generic type and use of construction product: Validité du : au : Validity from / to: 04/03/2011 04/03/2016 Usine de fabrication : Manufacturing plant: KNAUF EST F-68190 Ungersheim Le présent Agrément Technique Européen contient : This European Technical Approval contains: 23 pages incluant 6 pages de figures faisant partie intégrante du document 23 pages including 6 pages of figures which form an integral part of the document. Organisation pour l’Agrément Technique Européen European Organisation for Technical Approvals

Upload: others

Post on 10-Mar-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Centre Scientifique et

Technique du Bâtiment

84 avenue Jean Jaurès

Champs sur Marne

F-77447 Marne la Vallée Cedex 2

Tél. : (33) 01 64 68 82 82

Fax : (33) 01 60 05 70 37

Autorisé etnotifié conformément à

l’article 10 de la directive89/106/EEC du Conseil, du

21 décembre 1988, relative aurapprochement des dispositions

législatives, réglementaireset administratives des Etats

membres concernantles produits deconstruction.

MEMBRE DE L’EOTA

European Technical Approval - ETA 10/0328

(version originale en langue française)

Nom commercial :

Trade name:

Fibratec Ultra (Plâtre – ERP Plâtre – Vinyl – Lambris – Planche –

Acoustique - Particules) &

Fibratec FM Ultra (Plâtre – ERP Plâtre – Lambris – Planche)

Titulaire :

Holder of approval:

KNAUF SAS

Zone d’Activité

Rue Principale

68600 WOLFGANTZEN

Type générique et utilisation prévue du

produit de construction :

Self supporting composite lightweight panels for use in roofs.

Generic type and use of construction

product:

Validité du :

au :

Validity from / to:

04/03/2011

04/03/2016

Usine de fabrication :

Manufacturing plant:

KNAUF EST

F-68190 Ungersheim

Le présent Agrément Technique Européen

contient :

This European Technical Approval

contains:

23 pages incluant 6 pages de figures faisant partie intégrante du

document

23 pages including 6 pages of figures which form an integral part of the

document.

Organisation pour l’Agrément Technique Européen

European Organisation for Technical Approvals

Page 2: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 2 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

I LEGAL BASES AND GENERAL CONDITIONS

1 - This European Technical Approval is issued by the Centre Scientifique et Technique du

Bâtiment (CSTB) in accordance with :

- Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws,

regulations and administrative provisions of Member States relating to construction

products1

, modified by the Council Directive 93/68/EEC of 22 July 19932

;

- Décret n° 92-647 du 8 juillet 19923

concernant l’aptitude à l’usage des produits de

construction;

- Common Procedural Rules for Requesting, Preparing and the Granting of European

Technical Approvals set out in the Annex of Commission Decision 94/23/EC4

;

- Guideline for European Technical Approval 016 about self-supporting composite lightweight

panels – Part 2: Specific aspects for use in roofs.

2 - The Centre Scientifique et Technique du Bâtiment is authorised to check whether the provisions

of this European Technical Approval are met. Checking may take place in the manufacturing

plant (for example concerning the fulfilment of assumptions made in this European Technical

Approval with regard to manufacturing). Nevertheless, the responsibility for the conformity of the

products with the European Technical Approval and for their fitness for the intended use

remains with the holder of the European Technical Approval.

3 - This European Technical Approval is not to be transferred to manufacturers or agents of

manufacturer other than those laid down in the contact of the European Technical Approval; or

manufacturing plants other than those announced to the Centre Scientifique et Technique du

Bâtiment.

4 - This European Technical Approval may be withdrawn by the Centre Scientifique et Technique

du Bâtiment pursuant to Article 5 (1) of the Council Directive 89/106/EEC.

5 - Reproduction of this European Technical Approval including transmission by electronic means

shall be in full. However, partial reproduction can be made with the written consent of the Centre

Scientifique et Technique du Bâtiment. In this case, partial reproduction has to be designated as

such. Texts and drawings of advertising brochures shall not contradict or misuse the European

Technical Approval.

6 - The European Technical Approval is issued by the approval body in its official language. This

version fully corresponds to the version circulated within EOTA. Translations into other

languages have to be designated as such.

1 Official Journal of the European Communities no. L 40, 11.2.1989, p. 12

2 Official Journal of the European Communities no. L 220, 30./.1993, p. 1

3 Journal Officiel de la République française du 14 juillet 1992

4 Official Journal of the European Communities no. L 17, 20.1.1994, p. 34

Page 3: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 3 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

II SPECIFIC CONDITIONS OF THE EUROPEAN TECHNICAL APPROVAL

1 Definition of product and intended use

1.1 Scope

This ETA covers self supporting composite lightweight panels FIBRATEC for roofs or ceiling

insulating systems. The composite panels FIBRATEC do not contribute to the structural

stability. The tongue and groove assembly of the elements constitutes an insulating system.

The provisions made in this European Technical Approval (ETA) are based on an assumed

intended working life of at least 25 years, provided that the installed panels are subjected to

an appropriate use and maintenance.

The indications given as to the working life cannot be interpreted as a guarantee given by the

manufacturer, but should only be regarded as a means for choosing the appropriate

products in relation to the expected economically reasonable working life of the works.

1.2 Definition of Panels

FIBRATEC panels (cf. figure 1) are made of polystyrene PSE rigid foam, reference KNAUF

XTherm Ultra 32 FTEC SE, core glued to inner facing and outer facing. Counter-laths are

added on outer facing. The longitudinal joints are made by the fitment groove-matched

edges machined in insulation of the panels. A complement of sealing is ensured by foam PU

injection in the envisaged groove in higher of the panels. The panels are fixed with

mechanical fixings (nail or screw).

Page 4: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 4 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

Table 1 - Variants of FIBRATEC Panels :

Name components

FIBRATEC ULTRA PLATRE - counter battens

- particle board 3 mm

- insulation

- Gypsum Plaster board 12,5 mm

FIBRATEC ULTRA ERP PLATRE - counter battens

- particle board 3 mm

- insulation

- Gypsum Plaster board 18 mm

FIBRATEC ULTRA Vinyl - counter battens

- particle board 3 mm

- insulation

- Gypsum Plaster board 12,5 mm with vinyl

layer

FIBRATEC ULTRA LAMBRIS or PLANCHE - counter battens

- particle board 3 mm

- insulation

- Solid wood panel SWP

FIBRATEC ULTRA ACOUSTIQUE - counter battens

- particle board 3 mm

- insulation

- Wood wool layer thickness 25 mm with

aluminium film 40 µm

FIBRATEC ULTRA PARTICULES counter battens

- particle board 3 mm

- insulation

- particle board 12 mm

FIBRATEC FM ULTRA PLATRE - particle board 8 mm

- insulation

- Gypsum Plaster board 12,5 mm

FIBRATEC FM ULTRA ERP PLATRE - particle board 8 mm

- insulation

- Gypsum Plaster board 18 mm

FIBRATEC FM UTRA LAMBRIS / PLANCHE - particle board 8 mm

- insulation

- Solid wood panel SWP

Insulating PSE « Grey » ref : KNAUF XTherm Ultra 32 FTEC SE, CE marking according to EN

13163, with following characteristics :

Standard Thickness : 105, 120, 156, 205 mm ± 3 mm,

Other Thickness : 105 to 300 by step of 5 ± 3 mm,

width : 600 mm

Join : male – female (machining realised in factotry)

Thermal conductivity : Lambda D - 32 mW/(m.K),

compressive stress at 10 % deformation : 90 kPa

Tensile strength perpendicular to faces: 180 kPa,

Shear resistance :104 kPa,

Vapour permeability : 0,015 mg/(m.h.Pa)

Flame retardant HBCD.

Page 5: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 5 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

Inner facing is constituted by the following elements :

Gypsum plasterboard, thickness 12,5 mm ref : KH13 CE marking according to EN

520 :

o type H2

o thickness : 12,5 mm,

o width : 0,60 m,

o length : 3,00 and 4,00 m.

o Flexural strength:

Longitudinal direction : 60 daN

Transversal direction : 24 daN

o Total water absorption: ≤ 10 %,

o Surface water absorption: ≤ 180 g/m²,

o Edge and end profiles of gypsum plasterboards: Tapered edge,

o Euroclass for fire reaction of KNAUF Hydro KH : A2-s1,d0

Gypsum plasterboard, Thickness 18,0 mm ref : KH18, CE marking according to EN

520 :

o Type H2

o thickness: 18 mm,

o width : 0,60 m,

o length : 2,5 and 3,00 m.

o Flexural strength:

Longitudinal direction: 100 daN

Transversal direction: 40 daN

o Total water absorption: ≤ 10 %,

o Surface water absorption: 180 g/m².

o Edge and end profiles of gypsum plasterboards: Tapered edge,

o Euroclass for fire reaction of KNAUF Hydro KH : A2-s1,d0

Gypsum plasterboard, thickness 12,5 mm with vinyl layer ref: KNAUF Vinyl :

o Type H2 selon NF EN 520

o thickness : 12,5 mm,

o width : 0,60 m,

o longueur : 2.50, 3.00, 3.60 et 4.00 m.

o Flexural strength selon NF EN 520

Longitudinal direction: 60 daN

Transversal direction: 24 daN

o Total water absorption NF EN 520 : ≤ 10 %,

o Surface water absorption: ≤ 180 g/m²,

o Edge and end profiles of gypsum plasterboards: Half-rounded tapered

edge,

o lining : layer of fire proof PVC ignifugé Thickness. 0.2 mm, 260 g/m², with

colour, glued ,

o particleboard strip 12 x 40 mm added between the panels.

Wood wool layer thickness 25 mm with aluminium film 40 µm, ref : FIBRACOUSTIC

CB, CE marking according to EN 13168 :

o Thickness : 25mm

o width : 600 ± 2 mm

o length : 1500, 2000, 2500 ± 5 mm

o Longitudinal chamfering : 5 x 5 mm

o Surfacic weigth : 11,5 ± 1 kg/m²

o Euroclass for fire reaction: B s1 d0

o Thermal conductivity : 0,08 W/(m.K)

Page 6: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 6 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

Particleboard, Thickness 12 mm CE marking according to EN 13986 :

o Thickness : 12 ± 0,5mm

o density : 750 kg/m3

± 10%

o Humidity level : 5 à 13%

o Modulus of elasticity: ≥ 2555 MPa

o Mean stiffness values: ≥ 18 MPa

o Perpendicular Tensile strength: ≥ 0,45 MPa

o Perpendicular Tensile strength after V313: ≥ 0,25 MPa

o Swelling in thickness after 24h in water at 20°C : ≤ 11%

o Thermal conductivity : 0,18 W/m.K

o Formaldehyde level = classe E1

Solid wood panel SWP : Epicea, for panelling and cladding, Thickness 15 mm, CE

marking according to EN 13353

o width : 200 mm

o length : 2 m

o Transversal joins of cladding are out of line

o Density 410 kg/m3

,

Outer facing is constituted by the following elements :

Particle board, thickness 3 mm ref : MENDE, CE marking according to EN 13986 :

o Thickness : 3 ± 0,3 mm,

o Humidity level : 5 à 12 %,

o Swelling in thickness after 24h in water: ≤ 12 %,

o Perpendicular Tensile strength after V 100 : ≥ 0,15 N/mm²

o Mean stiffness values: ≥ 19 N/mm².

o width : 600 mm,

o length: in continu,

o density : 810 ± 10 % kg/m3

,

o Water resistance :

Swelling in thickness after V 313 : 12 % 1,5 %,

Dimensional variation after 24 heures in water :

longitudinal, 0,45 %,

transversal, 0,50 %.

o Tensile strength:

Initial mean value : 0,9 N/mm²,

after V 313 : 0,8 N/mm².

o Modulus of elasticity: ≥ 3 500 N/mm²,

o Thermal conductivity : 0,18 W/m.K,

o Formaldehyde level = 5,4 mg for 100 g of panel with internal humidity 6,5%

(Classe E1).

Particle board P5, thickness 8 mm CE marking according to EN 13986 :

o Thickness : 8 ± 0.3mm

o Density variation : ± 10%

o Humidity level : 5 à 13%

o Modulus of elasticity: ≥ 2550 MPa

o Mean stiffness values: ≥ 18 MPa

o Tensile strength: ≥ 0,45 MPa

o Swelling in thickness after 24h: ≤ 11%

o Thermal conductivity : 0,18 W/m.K

o density : 810 ± 10 % kg/m3

,

o Formaldehyde classe : E1

Wood counter battens are glued and staple all the 20 cm at the outer facing.

They have the following characteristics :

Page 7: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 7 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

o section : 24 mm (+ 0, - 2) x 47 mm (+ 0, - 2),

o mechanical class C24 according to EN 338,

o humidity level : 20 %,

o anticryptogamique treatment, use class 2 according to EN 355-2,

o stiffness: 12 MPa,

o Modulus of elasticity: 10 000 MPa.

The glue is made of polyurethane for assemblies insulation/faces and counter battens / outer

facing.

FIBRATEC panels have following characteristics :

length : 2,50 à 8,00 m by step of 0,10 m for gypsum plaster board inner facing and

Solid Wood Panel (LAMBRIS/PLANCHE) inner facing:

o Vinyl inner facing: 2,50 ; 3,00 ; 3,60 and 4,00m

o Wood wool inner facing : 2,50 ; 3,00, 4,00m and 5,00 m.

o Particle board inner facing : 3,00 and 4,00m

o Solid Wood Panel inner facing as FIBRATEC FM ULTRA

LAMBRIS/PLANCHE: 2,50 to 6,00 m by step of 0,10 m.

Use width : 600 mm

Total width : 615 mm

Dimensional variation in mm :

o on length : ± 10

o on width : ± 5

o on thickness : ± 3

1.3 Intended use

FIBRATEC panels always require external finishing layers including air cavity (tiles, covering

plate…) to provide waterproofing. These panels are only used in roof and these roofs are not

accessible.

1.4 Fixing devices

The manufacturer recommends the following fixing devices :

Insulation thickness (mm)

Support Fixing Diameter Length Characteristic

resistance

wood

Helix nail 6,5 mm Panel thickness

+ 60 mm 120 daN

Grooved nail 7 mm Panel thickness

+ 60 mm 120 daN

Metal screw+

washer 40 mm 6 mm

Panel thickness

+ 30 mm 260 daN

Page 8: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 8 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

1.5 join products for panels

The manufacturer recommends the following products:

outer facing

o longitudinal joins : polyurethane expanded foam

o Transversal joins : silicon mastic

Inner facing

o Plasterboard inner facing (KH 13 ou 18) : plaster KNAUF EJR, EJS, EJPN or EJPE and banner.

o Vinyl inner facing : particleboard strip 12x40mm.

Page 9: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 9 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

2 Characteristics of product and methods of verification

2.1 Mechanical resistance and stability

As the FIBRATEC panels are non-loadbearing parts of work, mechanical resistance is

considered under ER4 Safety in use (see § 2.4).

2.2 Safety in case of fire

2.2.1 Reaction to fire

No performance determined (Euroclass F).

2.2.2 Resistance to fire

No performance determined.

2.2.3 External fire performance

No performance determined.

2.3 Hygiene, health and environment

2.3.1 Water permeability

No performance determined.

2.3.2 Water vapour permeability (condensation risk)

No performance determined.

2.3.3 Release of dangerous substances

The information concerning the dangerous substances listed in Council Directive

67/548/EEC and Regulation (EC) No 1272/2008 regulated at European level and/or listed in

the "Indicative list on dangerous substances" of the EGDS and/or of other dangerous

substances, is indicated in the evaluation report

In addition to the specific clauses relating to dangerous substances contained in this ETA,

there may be other requirements applicable to the self-supporting composite lightweight

panels falling within its scope (e.g. transposed European Legislation and National law,

regulation, and administrative provisions). In order to meet the provisions of the EU

Construction Product Directive, these requirements need also to be complied with when and

where they applied.

According to the manufacturer’s declaration, the wood based boards that compose the

panels are classified as formaldehyde class E1 to EN 13986, and the content of

pentachlorophenol is <3 mg/kg.

Insulation contain flame retardant. The safety data sheet have been communicated to the

approval body.

The wood use for counter battens is treated to be in compliance with use classes 2 of the EN

335. The safety data sheet of the preservative product have been communicated to the

approval body. This product satisfies the requirements of Directive 98/8/EC on biocides.

Page 10: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 10 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

2.3.4 Dimentional variations

The dimensional variations of FIBRATEC panels have not been determined but the

experience provided since 1989 by the installation of more than 3 800 000 m² shows that the

product is satisfactory in regard to the dimensional variations.

2.4 Safety in use

2.4.1 Mechanical resistance

Tests are performed with two supported span panels and tests results are given in the table

in annex.

It has to be taken into account that the determination of mechanical resistance is the result of

three tests measurements, therefore the designer may apply the relevant safety factors

according to national practice and particular use.

Taking into account the fixing system with counter battens and cross fixing, the resistance

for negative load of the panels depend on the anchorage in support. It could be determined

by design according to EN 1995-1-1.

2.4.2 Impact resistance

Level of

accessibility

Impact resistance

walkability Use category Hard body

impact

Soft body

impact

Not accessible

roof NPD NPD NPD A1

2.4.3 Resistance to fixing

Resistance of the panels at fixings devices and joints

No performance determined.

Resistance to eccentric load due to objects fixed to the panel.

No performance determined.

2.4.4 Walkability

No performance determined.

2.5 Protection against noise

2.5.1 Sound insulation

No performance determined.

2.5.2 Acoustic absorption

No performance determined.

Page 11: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 11 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

2.6 Energy, economy and heat retention

2.6.1 Thermal insulation properties.

No performance determined.

2.6.2 Air permeability

No performance determined.

2.7 Durability and serviceability

2.7.1 Durability

Creep

The creep coefficient is determined by test according to annex C of the ETAG 016:

Time (hours) deflection(mm) Creep

coefficient

0 0,00 -

0,016 5,55 0,00

24 6,38 0,15

48 6,54 0,18

96 6,83 0,23

192 7,21 0,30

336 8,21 0,48

504 9 ,24 0,66

840 9,70 0,75

1008 9,90 0,78

1176 9,96 0,79

1344 9,98 0,80

1512 10,03 0,81

1920 10,05 0,81

2112 10,07 0,81

Thermal agents

When use in a roof, panels are not directly subjected to thermal shocks.

Biological agents

The wood use for the design of all variants of FIBRATEC panels is in compliance with use

classes 2 of the EN 335.

Page 12: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 12 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

3 Evaluation of conformity and CE marking

3.1 Attestation of conformity system

The system of attestation of conformity specified by the European Commission is system 3

for use subject to regulations on dangerous substances and system 4 for product

characteristics, according to Council Directive 89/106/EEC Annex III laid down by the

European Commission. These provisions are the following:

System 3 : FIBRATEC panels for use subject to regulations on dangerous substances

a) Tasks for the manufacturers:

Factory Production Control

Initial type testing of the product by a notify laboratory.

System 4

a) Tasks for the manufacturers:

– Factory Production Control

– Initial type testing of the product

3.2 Responsibilities

3.21 Tasks for the manufacturer

Factory production control

The personnel involved in the production process shall be identified, sufficiently qualified and

trained to operate and maintain the production equipment. Machinery equipment shall be

regularly maintained and this shall be documented. All processes and procedures of

production shall be recorded at regular intervals.

The manufacturer shall maintain a traceable documentation of the production process from

purchasing or delivery of raw or basic raw materials up to the storage and delivery of finished

products.

Products that do not comply with requirements as specified in the ETA shall be separated

from the conforming products and marked as such. The manufacturer shall register non-

compliant production and action(s) taken to prevent further non conformities. External

complaints shall also be documented, as well as actions taken.

Page 13: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 13 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

Declaration of conformity

When all the criteria of the Conformity Attestation are satisfied, the manufacturer shall make a

Declaration of Conformity.

On components (at reception) :

o Gypsum plasterboard : Thickness.

o Insulation : ACERMI controls,

o Wood: thickness, width, length, class

o particleboard : thickness, density, length.

During the manufacturing process :

o control on milling and rabbet,

o glue quantity,

o stick quality, linear weight and on m²,

o visual control (aspect, position, lining of wood and panels),

o piling control.

In laboratory (KNAUF-EST, UNGERSHEIM) on final products :

o Bending test with concentrated load,

o Deflection under dead weight,

o Tensile strength

o Plaster (strength ≥0,58 daN/cm²) and particle board (strength ≥0,70

daN/cm²).

When all the criteria of the Conformity Attestation are satisfied, the manufacturer shall make a

Declaration of Conformity.

3.22 Tasks for the manufacturer

Initial testing

This work should be taken over by the manufacturer for Declaration of Conformity purposes.

Page 14: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 14 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

3.3 CE MARKING

3.31 General

The CE marking shall be affixed either on the product it self, on a label attached to it, on the

packing or on the commercial document accompanying the panels.

The letters “CE” have to be followed by the identification number of the Approved

Certification Body involved and accompanied by the following information:

name or identifying mark and address of the ETA-holder,

information to clarify the intended use,

the last two digits of the year in which the CE marking was affixed,

number of the European Technical Approval,

relevant performance characteristics, as far as they are not specified in the ETA,

reference to the ETA Guideline.

3.32 Example

0679

“CE” Symbol

Number of notified body

KNAUF

Zone d’Activité

Rue Principale

68610 WOLFGANTZEN

XX

Name and address of the manufacturer or his representative

established in the EEA and of the plant where the product was

manufactured.

Two last digits of year of affixing CE Marking.

ETA N° 10/XXXX

ETAG 016, Part 1 and 2

Self-supporting

composite lightweight

panels for use in roofs

ETA Number.

ETAG Reference and date of publication.

3.33 Location of CE marking

The CE-marking will be affixed on the packaging of the self supporting composite lightweight

panels (each packaging to be marked). Panels should not be put on the market without

packaging.

Page 15: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 15 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

4. Assumptions under which the fitness of the product for the intended

use was favourably assessed

4.1 Manufacturing

The European Technical Approval is issued on the basis of agreed data/information,

deposited with Centre Scientifique et Technique du Bâtiment, which identifies panels that

has been assessed and judged. Changes to the panels or production process, which could

result in this deposited data/information being incorrect, should be notified to the Centre

Scientifique et Technique du Bâtiment before the changes are introduced. The Centre

Scientifique et Technique du Bâtiment will decide whether or not such changes affect the

ETA and consequently the validity of the CE marking on the basis of the ETA and if so

whether further assessment or alterations to the ETA, shall be necessary.

4.2 Design

It is the responsibility of the ETA-holder to guarantee that the information about design and

installation of these panels are easily accessible by the concerned people. This information

can be given using totals or partials reproductions of the European Technical Approval.

Besides, all the data concerning the execution shall be clearly indicated on the packaging

and/or the enclosed instruction sheets using one or several illustrations.

In any case, the user shall comply with the national regulations and particularly concerning

fire and wind load resistance.

Only the components described in clause 1.2 with characteristics according to clause 2 of

this ETA can be used.

4.3 Installation

The panels will be laid down perpendicularly to the supports which will be in solid wood or

metal. Each panel will lay down on three supports minimum, except if needed to complete

the raking and if the span is less than the maximum span reduced by 20%. Panels will be

nailed or screwed by at least two connectors on each support.

National law provisions shall always be taken into account.

Page 16: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 16 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

5. Recommandations

5.1 Packaging, transport and storage

Panels are packed on a pallet and protected by a plastic film. For most of the case, inferior

facing of the panel will stay visible, for that reason panels handling should be achieved with

great care.

Storage will be done with panels resting on wood supports and protected from rain and

moisture.

5.2 Maintenance and repair of the works

5.21 Use

The manufacturer shall provide to designers and users a set of details for the design of

buildings, with figures and technical data about the installation of the product. The

manufacturer shall also provide, if requested, a technician to oversee the installation of the

elements at the building site.

5.22 Panels repair

Panel replacement is not a particular matter, it has to be realized by a qualified company.

The original version is signed by:

Le Directeur Technique

C.BALOCHE

Page 17: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 17 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

Table for positive load :

Load

Insulation

thicknes (mm) Span (mm)

Panel length

(mm)

Ultimate load

(daN)

positive

105

1300 3100 3434

3210

3303

1750 4000 3158

2861

2516

2400 5300 2357

2298

2296

156

1600 3700 3784

3612

3734

2150 4800 3251

3096

2947

3000 6500 1931

2275

2314

205

1800 4100 3669

3616

3646

2350 5200 3440

3826

3645

3300 7100

2500

2637

2300

negative

105

1300 3100 2232

1750 4000 2102

2400 5300 1808

156

1600 3700 2244

2150 4800 1947

3000 6500 1619

205

1800 4100 2311

2350 5200 2366

3300 7100 1790

Page 18: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 18 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

1 –Counter battens

2- particle board 3 ou 8mm

3- Insulation

4- gypsum plaster board 13mm

Figure 1A –FIBRATEC Panels – Gypsum plaster board inner facing

1- particle board 3 ou 8mm

2- Insulation

3- gypsum plaster board 13 mm

Figure 1B – FIBRATEC Panels – Gypsum plaster board inner facing

Page 19: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 19 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

1-Counter battens

2- particle board 3 mm

3- Insulation

4- gypsum plaster board and vinyl

5-strip

Figure 1C – FIBRATEC Panels – Vinyl inner facing

1-Counter battens

2- particle board 3 mm

3- Insulation

4- Solid Wood Panel

Figure 1D – FIBRATEC Panels – LAMBRIS

Page 20: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 20 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

1- particle board 3 mm

2- Insulation

3- Solid Wood Panel

Figure 1E – FIBRATEC Panels – PLANCHE

Page 21: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 21 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

1-counter battens

2- particle board 3 mm

3- Insulation

4- particle board 12 mm

Figure 1F –FIBRATEC panels – particle board inner facing

1-counter battens

2- particle board 3 mm

3- Insulation

4- wood wool layer 25 mm

Figure 1G – FIBRATEC panels – wood wool layer inner facing

Page 22: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 22 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

1-counter battens

2- particle board 3 ou 8 mm

3- insulation

4- gypsum plaster board 18 mm

Figure 1H –FIBRATEC Panels – gypsum plaster board inner facing 18 mm

Figure 2 – longitudinal join

Page 23: European Technical Approval ETA 10/0328 - CSTBwebapp.cstb.fr/.../pdf/Doc_ETA_10_0328_UK.pdfPage 5 – European Technical Approval ETA 10/0328 Validity from 04/03/2011 to 04/03/2016

Page 23 – European Technical Approval ETA 10/0328

Validity from 04/03/2011 to 04/03/2016

Figure 3 – transversal join