For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected] This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA On Request Colors Fire retardant thermoplastic compound R16 PVC-based H.R. and O.R. suitable for CPR (R16 quality) Material SHEATH Natural Colors Fire retardant thermoplastic compound R16 PVC-based suitable for CPR (R16 quality) Material SHEATH 90 °C Max operating temperature 250 °C Max short circuit temperature 15 x Diam. Min. bending radius Mechanical and Installation: Electrical: 5000 MOhm x km Insulation resistance 4000 V a.c. x 10 min Dielectric test cond/cond 600/1000 V Voltage rating CHARACTERISTICS Wire armour with counter spiral tape Galvanized steel wire 0,6 mm 30 mm under armour diameter Galvanized steel wire 0,9 mm 30 mm under armour diameter Material ARMOUR Type Core are cabled with optimal lay lenght Type TOTAL CABLING On Request Colors Crosslinked elastomeric compound type HEPR suitable for CPR (G16 quality) Material INSULATION Flexible annealed bare copper cl.5 Material CONDUCTOR CABLE CONSTRUCTION AND SPECIFICATIONS IDENTIFICATION AND REACTION TO FIRE FG16OR16FR16 - 0,6/1 kV Cca-s3,d1,a3 DRAWING IS ONLY ILLUSTRATIVE CPR cable - INSTRUMENTATION CABLES FORELIND ® Special Electrical Cables

Upload: others

Post on 18-Dec-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DRAWING IS ONLY ILLUSTRATIVE CABLE CONSTRUCTION AND

For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA

FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected]

This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA

On RequestColors

Fire retardant thermoplastic compound R16 PVC-based H.R. and O.R. suitable for CPR (R16 quality)

MaterialSHEATH

NaturalColors

Fire retardant thermoplastic compound R16 PVC-based suitable for CPR (R16 quality)MaterialSHEATH

90 °CMax operating temperature

250 °CMax short circuit temperature

15 x Diam.Min. bending radiusMechanical and Installation:

Electrical:

≥ 5000 MOhm x kmInsulation resistance

4000 V a.c. x 10 minDielectric test cond/cond

600/1000 VVoltage rating

CHARACTERISTICS

Wire armour with counter spiral tape

Galvanized steel wire 0,6 mm ≤ 30 mm under armour diameter

Galvanized steel wire 0,9 mm ≥ 30 mm under armour diameter

Material

ARMOUR Type

Core are cabled with optimal lay lenghtTypeTOTAL CABLING

On RequestColors

Crosslinked elastomeric compound type HEPR suitable for CPR (G16 quality)MaterialINSULATION

Flexible annealed bare copper cl.5MaterialCONDUCTOR

CABLE CONSTRUCTION AND SPECIFICATIONS

IDENTIFICATION AND REACTION TO FIRE

FG16OR16FR16 - 0,6/1 kVCca-s3,d1,a3

DRAWING IS ONLY ILLUSTRATIVE

CPR cable - INSTRUMENTATION CABLES

FORELIND®

Special Electrical Cables

Page 2: DRAWING IS ONLY ILLUSTRATIVE CABLE CONSTRUCTION AND

CEI 20-13 PQA - -Rubber insulated cables with rated voltages between 1 kV and 30 kV (where applicable)

CEI 20-11/0-1;V1 - -National annex to EN 50363-0: Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General Introduction

CEI 20-29 IEC 60228 EN 60228 (CEI EN 60228)

Conductors of insulated cables

STANDARDS OR SPECIFICATIONS CONSTRUCTION

For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA

FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected]

This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA

DATASHEET

PAGE 02CPR cable - INSTRUMENTATION CABLES

FORELIND®

Special Electrical Cables

CEI 20-108 - EN 50399(CEI EN 50399)

Common test methods for cables under fire conditions - Heat release and smoke production measurement on cables during flame spread test - Test apparatus, procedures, results

CEI 20-35/1-2 IEC 60332-1-2 EN 60332-1-2(CEI EN 60332-1-2)

Test on electric and optical fibre under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame

STANDARDS OR SPECIFICATIONS TEST

Page 3: DRAWING IS ONLY ILLUSTRATIVE CABLE CONSTRUCTION AND

For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA

FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected]

This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA

9000

9001

9002

9003

9004

9056

9005

9006

9007

9008

9009

9010

325

352

391

439

498834

711

834

1087

379

414

470

13,42

13,89

14,65

15,49

16,47

20,78

20,06

21,66

24,91

14,36

14,91

15,78

7,92

8,39

9,15

9,99

10,97

15,28

14,5616,16

19,41

8,86

9,41

10,28

13,3

13,3

13,3

13,3

13,3

13,3

13,3

13,3

13,3

7,98

7,98

7,98

FG16OR16FR16 - 0,6/1 kV - 2x1,5 mm2

FG16OR16FR16 - 0,6/1 kV - 3x1,5 mm2

FG16OR16FR16 - 0,6/1 kV - 4x1,5 mm2

FG16OR16FR16 - 0,6/1 kV - 5x1,5 mm2

FG16OR16FR16 - 0,6/1 kV - 7x1,5 mm2

FG16OR16FR16 - 0,6/1 kV - 10x1,5 mm2

FG16OR16FR16 - 0,6/1 kV - 12x1,5 mm2

FG16OR16FR16 - 0,6/1 kV - 16x1,5 mm2

FG16OR16FR16 - 0,6/1 kV - 24x1,5 mm2

FG16OR16FR16 - 0,6/1 kV - 2x2,5 mm2

FG16OR16FR16 - 0,6/1 kV - 3x2,5 mm2

FG16OR16FR16 - 0,6/1 kV - 4x2,5 mm2

Ohm/km mm mm kg/km

Max conductorresistance at 20°C

Nom. Underarmour Ø

Nom. Outer Ø Nom. Weight P/NIDENTIFICATION ( * )

9011

9012

9055

9013

9014

9015

9016

9017

9018

9057

9019

9020

534

623

665

901

10741452

457

513

588

705

534

621

16,76

18,03

18,99

22,01

23,87

27,94

15,54

16,18

17,2

18,45

16,6

17,33

11,26

12,53

13,49

16,51

18,37

22,24

10,0410,68

11,7

12,95

11,1

11,83

7,98

7,98

7,98

7,98

7,98

7,98

4,95

4,95

4,95

4,95

3,3

3,3

FG16OR16FR16 - 0,6/1 kV - 5x2,5 mm2

FG16OR16FR16 - 0,6/1 kV - 7x2,5 mm2

FG16OR16FR16 - 0,6/1 kV - 10x2,5 mm2

FG16OR16FR16 - 0,6/1 kV - 12x2,5 mm2

FG16OR16FR16 - 0,6/1 kV - 16x2,5 mm2

FG16OR16FR16 - 0,6/1 kV - 24x2,5 mm2

FG16OR16FR16 - 0,6/1 kV - 2x4 mm2

FG16OR16FR16 - 0,6/1 kV - 3x4 mm2

FG16OR16FR16 - 0,6/1 kV - 4x4 mm2

FG16OR16FR16 - 0,6/1 kV - 5x4 mm2

FG16OR16FR16 - 0,6/1 kV - 2x6 mm2

FG16OR16FR16 - 0,6/1 kV - 3x6 mm2

9021

9058

9022

9023

9024

9059

9025

9026

708

845

695

808

9481142

1012

1198

18,58

18,89

18,54

19,42

20,8

22,37

22,22

23,39

13,08

14,39

13,04

13,92

15,3

16,87

16,7217,89

3,3

3,3

1,91

1,91

1,91

1,91

1,21

1,21

FG16OR16FR16 - 0,6/1 kV - 4x6 mm2

FG16OR16FR16 - 0,6/1 kV - 5x6 mm2

FG16OR16FR16 - 0,6/1 kV - 2x10 mm2

FG16OR16FR16 - 0,6/1 kV - 3x10 mm2

FG16OR16FR16 - 0,6/1 kV - 4x10 mm2

FG16OR16FR16 - 0,6/1 kV - 5x10 mm2

FG16OR16FR16 - 0,6/1 kV - 2x16 mm2

FG16OR16FR16 - 0,6/1 kV - 3x16 mm2

( * ) Any other identification on request. Please contact our technical department

DATASHEET

PAGE 03CPR cable - INSTRUMENTATION CABLES

FORELIND®

Special Electrical Cables

Page 4: DRAWING IS ONLY ILLUSTRATIVE CABLE CONSTRUCTION AND

For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA

FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected]

This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA

9027

9060

9028

9029

9030

9061

9031

9032

9033

9065

9062

1428

16,92

1297

1574

19252326

1759

2149

2505

2646

3405

25,25

27,64

24,2

25,53

27,94

30,53

28,9

30,8

32,57

33,97

37,77

19,75

21,94

18,7

20,03

22,24

24,61

23,224,88

24,45

27,85

30,85

1,21

1,21

0,78

0,78

0,78

0,78

0,554

0,554

0,554 for 35 mmq 0,780 for 25 mmq

0,554

0,554

FG16OR16FR16 - 0,6/1 kV - 4x16 mm2

FG16OR16FR16 - 0,6/1 kV - 5x16 mm2

FG16OR16FR16 - 0,6/1 kV - 2x25 mm2

FG16OR16FR16 - 0,6/1 kV - 3x25 mm2

FG16OR16FR16 - 0,6/1 kV - 4x25 mm2

FG16OR16FR16 - 0,6/1 kV - 5x25 mm2

FG16OR16FR16 - 0,6/1 kV - 2x35 mm2

FG16OR16FR16 - 0,6/1 kV - 3x35 mm2

FG16OR16FR16 - 0,6/1 kV - 3x35+1X25 mm2

FG16OR16FR16 - 0,6/1 kV - 4x35 mm2

FG16OR16FR16 - 0,6/1 kV - 5x35 mm2

Ohm/km mm mm kg/km

Max conductorresistance at 20°C

Nom. Underarmour Ø

Nom. Outer Ø Nom. Weight P/NIDENTIFICATION ( * )

9034

9035

9036

9063

9037

9038

9039

9040

9041

9042

2406

2952

3460

44842844

3981

4456

4029

5030

5717

33,86

36,08

37,71

43,91

34,78

38,56

39,79

42,76

45,99

47,86

27,74

29,76

30,79

36,57

28,66

32,91

32,65

35,42

38,45

40,32

0,386

0,386

0,386 for 50 mmq 0,780 for 25 mmq

0,386

0,272

0,272

0,272 for 70 mmq 0,554 for 35 mmq

0,206

0,206

0,206 for 95 mmq 0,386 for 50 mmq

FG16OR16FR16 - 0,6/1 kV - 2x50 mm2

FG16OR16FR16 - 0,6/1 kV - 3x50 mm2

FG16OR16FR16 - 0,6/1 kV - 3x50+1x25 mm2

FG16OR16FR16 - 0,6/1 kV - 5x50 mm2

FG16OR16FR16 - 0,6/1 kV - 2x70 mm2

FG16OR16FR16 - 0,6/1 kV - 3x70 mm2

FG16OR16FR16 - 0,6/1 kV - 3x70+1x35 mm2

FG16OR16FR16 - 0,6/1 kV - 2x95 mm2

FG16OR16FR16 - 0,6/1 kV - 3x95 mm2

FG16OR16FR16 - 0,6/1 kV - 3x95+1x50 mm2

9064

9043

9044

9045

9046

9047

6167

4415

5629

6616

5935

7380

50,37

42,3

45,5

47,95

52,04

55,53

42,63

34,96

37,96

40,41

44,0847,37

0,206

0,161

0,161

0,161 for 120 mmq 0,272 for 70 mmq

0,129

0,129

FG16OR16FR16 - 0,6/1 kV - 4x95 mm2

FG16OR16FR16 - 0,6/1 kV - 2x120 mm2

FG16OR16FR16 - 0,6/1 kV - 3x120 mm2

FG16OR16FR16 - 0,6/1 kV - 3x120+1x70 mm2

FG16OR16FR16 - 0,6/1 kV - 2x150 mm2

FG16OR16FR16 - 0,6/1 kV - 3x150 mm2

( * ) Any other identification on request. Please contact our technical department

DATASHEET

PAGE 04CPR cable - INSTRUMENTATION CABLES

FORELIND®

Special Electrical Cables

Page 5: DRAWING IS ONLY ILLUSTRATIVE CABLE CONSTRUCTION AND

For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA

FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected]

This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA

9048

9049

9050

9051

9052

9053

9054

8185

6338

8083

9301

8979

11386

13214

53,06

50,82

54,45

56,65

61,86

66,07

69,22

50,39

43,08

46,29

48,49

53,2827,29

57,04

0,129 for 150 mmq 0,206 for 95 mmq

0,106

0,106

0,106 for 185 mmq 0,206 for 95 mmq

0,0801

0,0801

0,0801 for 240 mmq 0,129 for 150 mmq

FG16OR16FR16 - 0,6/1 kV - 3x150+1x95 mm2

FG16OR16FR16 - 0,6/1 kV - 2x185 mm2

FG16OR16FR16 - 0,6/1 kV - 3x185 mm2

FG16OR16FR16 - 0,6/1 kV - 3x185+1x95 mm2

FG16OR16FR16 - 0,6/1 kV - 2x240 mm2

FG16OR16FR16 - 0,6/1 kV - 3x240 mm2

FG16OR16FR16 - 0,6/1 kV - 3x240+1x150 mm2

Ohm/km mm mm kg/km

Max conductorresistance at 20°C

Nom. Underarmour Ø

Nom. Outer Ø Nom. Weight P/NIDENTIFICATION ( * )

( * ) Any other identification on request. Please contact our technical department

DATASHEET

PAGE 05CPR cable - INSTRUMENTATION CABLES

FORELIND®

Special Electrical Cables

Page 6: DRAWING IS ONLY ILLUSTRATIVE CABLE CONSTRUCTION AND

Via Europa, 6 - 24055 Cologno al Serio (BG - ITALY)Phone + 39 035 899191 - Fax + 39 035 4819224www.forelind.com E-mail: [email protected]

FOR.EL.IND S.p.A.

Special Electrical Cables

®

FORELIND