département du gard · etudes geologiques * geotechniques * hydrogeologiques * assainissement...

12
CFEG C OMPAGNIE F RANÇAISE D 'E TUDES G EOTECHNIQUES D D é é p p a a r r t t e e m m e e n n t t d d u u G G A A R R D D Commune de VALLABRIX Commune de VALLABRIX Commune de VALLABRIX Commune de VALLABRIX _________ Chemin de Saint Eloi / BP 14 / 91720 MAISSE ______ C C A A R R R R I I E E R R E E D D E E B B R R U U G G A A S S P P P R R R O O O J J J E E E T T T D D D E E E S S S T T T A A A B B B I I I L L L I I I S S S A A A T T T I I I O O O N N N E E E T T T D D D E E E T T T R R R A A A I I I T T T E E E M M M E E E N N N T T T D D D E E E S S S G G G R R R I I I F F F F F F E E E S S S D D D ' ' ' E E E R R R O O O S S S I I I O O O N N N / / / S S S E E E C C C T T T E E E U U U R R R E E E S S S T T T E. 167/09 E. 167/09 E. 167/09 E. 167/09-1 Gérard PAPPINI Juin 2009 46, rue Marcel Girardin - 69330 MEYZIEU Téléphone : 04 78 31 64 30 Télécopie : 04 78 31 41 21 e.mail : cfeg@wanadoo.fr ETUDES GEOLOGIQUES * GEOTECHNIQUES * HYDROGEOLOGIQUES * ASSAINISSEMENT S.A.R.L AU CAPITAL DE 22 200 / R.C.S. LYON 302 411 525 / SIRET 302 411 525 00025 / NAF 7112 B / N° TVA CE FR 86 302411 525

Upload: buikhue

Post on 14-Sep-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Département du GARD · etudes geologiques * geotechniques * hydrogeologiques * assainissement s.a.r.l au capital de 22 200 € / r.c.s. lyon 302 411 525 / siret 302 411 525 00025

CFEG C O M P A G N I E F R A N Ç A I S E D ' E T U D E S G E O T E C H N I Q U E S

DDDééépppaaarrr ttteeemmmeeennnttt ddduuu GGGAAARRRDDD

Commune de VALLABRIXCommune de VALLABRIXCommune de VALLABRIXCommune de VALLABRIX _________

� Chemin de Saint Eloi / BP 14 / 91720 MAISSE �

______

CCCAAARRRRRRIIIEEERRREEE DDDEEE BBBRRRUUUGGGAAASSS

PPPPPPPPPPPPRRRRRRRRRRRROOOOOOOOOOOOJJJJJJJJJJJJEEEEEEEEEEEETTTTTTTTTTTT DDDDDDDDDDDDEEEEEEEEEEEE SSSSSSSSSSSSTTTTTTTTTTTTAAAAAAAAAAAABBBBBBBBBBBBIIIIIIIIIIIILLLLLLLLLLLLIIIIIIIIIIIISSSSSSSSSSSSAAAAAAAAAAAATTTTTTTTTTTTIIIIIIIIIIIIOOOOOOOOOOOONNNNNNNNNNNN EEEEEEEEEEEETTTTTTTTTTTT DDDDDDDDDDDDEEEEEEEEEEEE TTTTTTTTTTTTRRRRRRRRRRRRAAAAAAAAAAAAIIIIIIIIIIIITTTTTTTTTTTTEEEEEEEEEEEEMMMMMMMMMMMMEEEEEEEEEEEENNNNNNNNNNNNTTTTTTTTTTTT

DDDDDDDDDDDDEEEEEEEEEEEESSSSSSSSSSSS GGGGGGGGGGGGRRRRRRRRRRRRIIIIIIIIIIIIFFFFFFFFFFFFFFFFFFFFFFFFEEEEEEEEEEEESSSSSSSSSSSS DDDDDDDDDDDD''''''''''''EEEEEEEEEEEERRRRRRRRRRRROOOOOOOOOOOOSSSSSSSSSSSSIIIIIIIIIIIIOOOOOOOOOOOONNNNNNNNNNNN //////////// SSSSSSSSSSSSEEEEEEEEEEEECCCCCCCCCCCCTTTTTTTTTTTTEEEEEEEEEEEEUUUUUUUUUUUURRRRRRRRRRRR EEEEEEEEEEEESSSSSSSSSSSSTTTTTTTTTTTT

E. 167/09E. 167/09E. 167/09E. 167/09----1111

Gérard PAPPINI Juin 2009

46, rue Marcel Girardin - 69330 MEYZIEU � Téléphone : 04 78 31 64 30 � Télécopie : 04 78 31 41 21 � e.mail : [email protected]

ETUDES GEOLOGIQUES * GEOTECHNIQUES * HYDROGEOL OGIQUES * ASSAINISSEMENT S.A.R.L AU CAPITAL DE 22 200 € / R.C.S. LYON 302 411 525 / SIRET 302 411 525 00025 / NAF 7112 B / N° TVA CE FR 86 302411 525

Page 2: Département du GARD · etudes geologiques * geotechniques * hydrogeologiques * assainissement s.a.r.l au capital de 22 200 € / r.c.s. lyon 302 411 525 / siret 302 411 525 00025

CFEG - E. 167/09-1 - Juin 2009

FULCHIRON S.A. / VALLABRIX / CARRIERE DE BRUGAS / PROJET DE STABILISATION ET DE TRAITEMENT DES GRIFFES D'EROSION / SECTEUR EST

2

1 - OBJET

Ce rapport fait suite à notre visite du 16 Juin 2009 et à notre avant projet (rapport CFEG

E. 167/09 du 19 Juin 2009), effectués dans le cadre du suivi du projet de stabilisation des

griffes (canyon) d'érosion, dans le secteur Est de la carrière de BRUGAS sur la commune

de VALLABRIX (cf. Fig. 1 ; p. 3).

Il a pour objet de préciser, dans l'environnement immédiat des canyons :

- les conditions de terrassements,

- les limites de ces terrassements,

- les conditions de comblement des griffes restantes,

- les conditions de maîtrise du ruissellement susceptibles de stopper l'érosion.

à la suite du levé topographique du secteur qui vient d'être réalisé en Juin 2009 par les

géomètres LESENNE / MARTINEZ, 8ter, impasse Gaston Blanc / 30 000 NIMES.

Le développement rapide des griffes d'érosion constaté depuis plusieurs mois dans le

secteur Est de la carrière, et notamment dans le versant qui domine des bassins de

décantation des boues, nécessite des travaux de stabilisation et de traitement.

Jusqu'à ce jour, un fossé de 5 à 7 m de profondeur, terrassé au pied des canyons, assurait

la rétention des sables déstabilisés / érodés et l'infiltration des eaux de ruissellement.

L'évolution régressive et le danger que représentent les parois subverticales de 10 à 30 m

de hauteur conduisent à rechercher une solution pérenne de stabilisation.

2 PROPOSITION DE STABILISATION ET DE TRAITEMENT EN AMONT DES BASSINS DE DECANTATION DES BOUES

Les aménagements nécessaires pour stabiliser les canyons sont conditionnés par

l'approvisionnement en enrochements. Le stock de blocs de quartzites disponibles au

"col" a été utilisé en totalité, pour :

- la réalisation du bassin écrêteur du Valadas et des aménagements annexes,

- la pose de filtres à la base des canyons "A" et "C",

- la protection ponctuelle des berges du Valadas amont (masquées à l'exutoire

du canyon "B" et autres).

Pour l'ensemble de ces travaux, le volume d'enrochements transportés et agencés est

estimé à 2 000 m3.

Page 3: Département du GARD · etudes geologiques * geotechniques * hydrogeologiques * assainissement s.a.r.l au capital de 22 200 € / r.c.s. lyon 302 411 525 / siret 302 411 525 00025

CFEG - E. 167/09-1 - Juin 2009

FULCHIRON S.A. / VALLABRIX / CARRIERE DE BRUGAS / PROJET DE STABILISATION ET DE TRAITEMENT DES GRIFFES D'EROSION / SECTEUR EST

3

CFEG - E. 167/09-1 – Juin 2009

3

Fig. 1 : PROJET DE STABILISATION ET DE TRAITEMENT

CANYONS "C" à "E"

Echelle = 1/1000

Page 4: Département du GARD · etudes geologiques * geotechniques * hydrogeologiques * assainissement s.a.r.l au capital de 22 200 € / r.c.s. lyon 302 411 525 / siret 302 411 525 00025

CFEG - E. 167/09-1 - Juin 2009

FULCHIRON S.A. / VALLABRIX / CARRIERE DE BRUGAS / PROJET DE STABILISATION ET DE TRAITEMENT DES GRIFFES D'EROSION / SECTEUR EST

4

Les aménagements en cours :

- prolongement du filtre en enrochements dans le canyon "A", (270 m3

d'enrochements),

- poursuite de la protection /stabilisation des stocks en aval des bassins de

décantation des boues,

, sont donc tributaires des possibilités d'un emprunt de quartzites dans l'environnement

de la carrière ou à proximité de ses limites actuellement autorisées.

Le projet de stabilisation des canyons "C", "D", et "E", nécessitera des volumes

supplémentaires d'enrochements non disponibles à ce jour.

2.1 - Définition du périmètre à traiter

Ce secteur, d'environ 250 ml, intéresse le canyon "C", ainsi que les 2 canyons régressifs

situés à l'Ouest de ce dernier (appelés par simplification "D" et "E", d'Est en Ouest ; cf.

Fig. 1 ; p. 3).

2.2 - Objectif des travaux

L'objectif est de stabiliser le versant en appliquant les préconisations suivantes :

- Suppression d'une partie des canyons ou réduction de la hauteur des parois

instables,

- Création de banquettes aménagées en "casiers" pour confiner les eaux

météoriques et de ce fait supprimer le ruissellement,

- Comblement des dépressions restantes avec des argiles décantées ou des

stériles de carrière non érodables,

- Sécurisation des remblais : butées en enrochements ; respect des pentes

d'équilibre supposées pour les argiles déversées (12° / horizontale).

2.3 - Projet / Phasage (cf. Fig. 1 ; p. 3 et Profils 1 à 9 ; pp. 5 à 7).

2.3.1 - Terrassements

Le projet s'appuie sur le levé topographique récent, effectué en juin 2009 par le Cabinet

de Géomètres-Experts LESENNE – MARTINEZ ; il prend en compte les travaux

d'extraction qui ont débuté au Nord-Est du "Col" (cotes 226/227) en aval des bornes n°

125, 126 et 127 (cf. Fig. 1).

Page 5: Département du GARD · etudes geologiques * geotechniques * hydrogeologiques * assainissement s.a.r.l au capital de 22 200 € / r.c.s. lyon 302 411 525 / siret 302 411 525 00025

CFEG - E. 167/09-1 - Juin 2009

FULCHIRON S.A. / VALLABRIX / CARRIERE DE BRUGAS / PROJET DE STABILISATION ET DE TRAITEMENT DES GRIFFES D'EROSION / SECTEUR EST

5

CANYON "C"

PROFILS 1 - 2 et 3

Echelle = 1/1000

Page 6: Département du GARD · etudes geologiques * geotechniques * hydrogeologiques * assainissement s.a.r.l au capital de 22 200 € / r.c.s. lyon 302 411 525 / siret 302 411 525 00025

CFEG - E. 167/09-1 - Juin 2009

FULCHIRON S.A. / VALLABRIX / CARRIERE DE BRUGAS / PROJET DE STABILISATION ET DE TRAITEMENT DES GRIFFES D'EROSION / SECTEUR EST

6

CANYON "D"

PROFILS 4 - 5 et 6

Echelle = 1/1000

Page 7: Département du GARD · etudes geologiques * geotechniques * hydrogeologiques * assainissement s.a.r.l au capital de 22 200 € / r.c.s. lyon 302 411 525 / siret 302 411 525 00025

CFEG - E. 167/09-1 - Juin 2009

FULCHIRON S.A. / VALLABRIX / CARRIERE DE BRUGAS / PROJET DE STABILISATION ET DE TRAITEMENT DES GRIFFES D'EROSION / SECTEUR EST

7

CANYON "E"

PROFILS 7 - 8 et 9

Echelle = 1/1000

Page 8: Département du GARD · etudes geologiques * geotechniques * hydrogeologiques * assainissement s.a.r.l au capital de 22 200 € / r.c.s. lyon 302 411 525 / siret 302 411 525 00025

CFEG - E. 167/09-1 - Juin 2009

FULCHIRON S.A. / VALLABRIX / CARRIERE DE BRUGAS / PROJET DE STABILISATION ET DE TRAITEMENT DES GRIFFES D'EROSION / SECTEUR EST

8

→→→→ Les travaux suivants seront réalisés simultanément en aval et en amont :

• En aval :

- Préparation des butées en enrochements à l'exutoire des canyons "C" et "D",

- Terrassement d'une rampe à l'exutoire du canyon "C" (cote 185/188) pour

faciliter l'agencement des enrochements et le déversement des boues.

• En amont :

- Dégagement de la plate-forme "230" depuis la zone d'extraction actuelle (cf.

Profil 7).

- Acheminement des matériaux sableux par la rampe d'accès (11% à 14%)

proposée dans notre C.R. CFEG – E. 133/09 de Mai 2009.

→→→→ Le traitement du versant se poursuivra du Sud vers le Nord et d'amont en aval.

Chaque gradin aura la géométrie suivante :

- banquettes horizontales de 15 m minimum de largeur,

- talus amont : penté à 75°/horizontale ; hauteur = 10 m.

- banquettes aménagées en "casiers" et végétalisées à l'avancement.

→→→→ Le talus aval de la banquette "210" atteindra la falaise sableuse du canyon "D" et

d'un diverticule à l'Est. La banquette sera utilisée pour acheminer et déverser les

boues dans ce canyon.

→→→→ Au Sud du canyon "D" l'aménagement de la plate-forme "200" s'effectuera depuis

la piste d'accès au col (cotes 204 – 206).

La banquette "190" sera terrassée et les matériaux évacués par "jets de pelle".

→→→→ Au Nord du canyon "D" la banquette "200" sera terrassée du Sud vers le Nord ; les

matériaux extraits seront transportés en utilisant la banquette supérieure (cote 210)

puis progressivement en amont des canyons "C", évacués par verse.

Les matériaux sableux issus des terrassements de la banquette "190" seront déversés

dans le talus aval et évacués.

→→→→ Au fur et à mesure de l'avancement des terrassements, les banquettes "200" et

"190" faciliteront l'acheminement des boues et stériles de comblement du canyon

"D".

Page 9: Département du GARD · etudes geologiques * geotechniques * hydrogeologiques * assainissement s.a.r.l au capital de 22 200 € / r.c.s. lyon 302 411 525 / siret 302 411 525 00025

CFEG - E. 167/09-1 - Juin 2009

FULCHIRON S.A. / VALLABRIX / CARRIERE DE BRUGAS / PROJET DE STABILISATION ET DE TRAITEMENT DES GRIFFES D'EROSION / SECTEUR EST

9

2.3.2 - Enrochements (cf. Fig. 2 ; p. 10).

Les enrochements intéresseront principalement la base du canyon "D" ; ils seront placés

dans une bêche constituée par le fossé existant dans le gisement en place.

La butée sera agencée sur toute la largeur du canyon sur 5 m de hauteur, avec une pente

de 30° / horizontale.

Si nécessaire, les enrochements seront rehaussés au fur et à mesure du remplissage

argileux et de stériles.

Les schémas de principe sont applicables à l'ensemble des griffes d'érosion de ce secteur ;

des adaptations seront nécessaires en fonction :

- de la géométrie détaillée de chaque canyon,

- des instabilités qui se manifesteraient pendant les travaux,

- des possibilités d'approvisionnement en matériaux rocheux.

- L'avancement de ces travaux sera conditionné par deux facteurs principaux :

- capacité d'approvisionnement en matériaux rocheux (le volume est estimé à

2200 m3 à l'aval du canyon "D" et à 4 200 m3 pour l'ensemble du site).

- conditions météorologiques favorables pour l'acheminement des boues et des

stériles à déverser depuis les banquettes.

2.3.3 - Distances de sécurité

Elles ont été étudiées et exposées dans le rapport CFEG E. 163/04 de Juin 2004.

Compte-tenu des caractéristiques mécaniques des sables et notamment de la perte quasi-

totale de la cohésion du fait du remaniement induit par les terrassements :

- décompression,

- augmentation de la teneur en eau,

, des risques d'instabilité sont à prendre en compte.

Afin de s'affranchir de ces risques, la circulation d'engins ne devra s'opérer qu'au-delà

d'une distance minimale de 3,50 m depuis la crête de talus, et si possible au pied du

talus amont de la banquette.

Page 10: Département du GARD · etudes geologiques * geotechniques * hydrogeologiques * assainissement s.a.r.l au capital de 22 200 € / r.c.s. lyon 302 411 525 / siret 302 411 525 00025

CFEG - E. 167/09-1 - Juin 2009

FULCHIRON S.A. / VALLABRIX / CARRIERE DE BRUGAS / PROJET DE STABILISATION ET DE TRAITEMENT DES GRIFFES D'EROSION / SECTEUR EST

10

Fig. 2

CANYON "D" - PROJET

PROFIL EN LONG Echelle = 1/500

PROFIL EN TRAVERS

Echelle = 1/500

Page 11: Département du GARD · etudes geologiques * geotechniques * hydrogeologiques * assainissement s.a.r.l au capital de 22 200 € / r.c.s. lyon 302 411 525 / siret 302 411 525 00025

CFEG - E. 167/09-1 - Juin 2009

FULCHIRON S.A. / VALLABRIX / CARRIERE DE BRUGAS / PROJET DE STABILISATION ET DE TRAITEMENT DES GRIFFES D'EROSION / SECTEUR EST

11

2.3.4 - Volumes estimés

Le traitement et la stabilisation du versant nécessitent son terrassement sur environ

2,5 hectares, et par conséquent un déboisement partiel entre les profils 1 et 7 (# 1,5 ha).

Les volumes extraits estimés à partir du plan topographique de Juin 2009 sont les suivants

(Profils 1 à 9) :

Cote banquette Volumes extraits

(m3)

230 18 200

220 40 200

20 46 300

200 42 500

190 32 200

Total : 179 400 m3

Ces volumes prennent en compte le gisement sableux en cours d'extraction au Nord-Est

immédiat du col (Profils 7 à 9), qui représente environ 80 000 m3 de réserve.

Le traitement et la stabilisation des canyons "C" et "D" impliquent un terrassement voisin

de 99 000 m3 (Profils 1 à 6).

3 - CONCLUSIONS

� Les travaux de stabilisation et de traitement des canyons ne peuvent être envisagés et

effectués que par le terrassement du versant qui permet :

- de supprimer la majorité des couloirs d'érosion,

- de limiter les hauteurs de falaise sableuse et les risques de chute de

matériaux de grande ampleur dans le canyon "D",

- de stopper le ruissellement en confinant les eaux sur les banquettes au

moyen de "casiers",

- de protéger les falaises restantes avec des argiles décantées et des

stériles de carrière inertes.

Page 12: Département du GARD · etudes geologiques * geotechniques * hydrogeologiques * assainissement s.a.r.l au capital de 22 200 € / r.c.s. lyon 302 411 525 / siret 302 411 525 00025

CFEG - E. 167/09-1 - Juin 2009

FULCHIRON S.A. / VALLABRIX / CARRIERE DE BRUGAS / PROJET DE STABILISATION ET DE TRAITEMENT DES GRIFFES D'EROSION / SECTEUR EST

12

� Les remblais argileux seront contenus derrière une butée en enrochements.

� Chaque banquette terminée sera aménagée en "casiers" et végétalisée.

Pour éviter l'érosion régressive, très active, dans ces matériaux sableux peu cohérents,

nous proposons d'entreprendre rapidement le traitement du versant ; toutefois, l'évolution

des travaux de stabilisation est liée aux possibilités d'approvisionnement en

enrochements.

_________________

Fait à Meyzieu, le 30 Juin 2009

Gérard PAPPINI Docteur en Géologie Appliquée